CDD‐LIVE
Wiring Instructions
Wiring instructions for the Neutrik® PowerCon True1 are as follows. Note that all mains wiring should be carried out by a
competent, trained technician. If a suitable technician is not available Martin Audio would recommend purchasing one of the
range of pre‐made mains cables available as optional accessories. These feature the PowerCon True1 connector on a flexible
cable of either 2.15m (part number ASF12024) or 5m (part number ASF12023) in length and are terminated in a 16A male
Ceeform connector. Both cables are rated to IP67.
Approval based:
Rating:
Cable Type:
Strain Relief:
Cable O.D.:
A Prepare cable as
shown
CDD‐LIVE User Guide V1.0
USER GUIDE
VDE
EN 60320
250 V ac / 16A
H05VV‐F3G 1.0mm², Length max. 2m
H05VV‐F3G 1.5 – 2.5mm²
H07RN‐F3G 1.5mm²
White Chuck
6.0 – 12.0 mm
UL
UL 498 / C22.2 No. 182.3
250 V ac / 20 A
SJTOW, SJOOW 3 x 12 AWG
White Chuck
6.0 – 12.0 mm
17