fasteners from magazine before making any adjustments or servicing this tool.
SYMPTOM
Air leak near top of tool or in trigger area
Tool does nothing or operates sluggishly
Air leak near bottom of tool
Tool jams or skips frequently
Other

TROUBLESHOOTING GUIDE

WARNING: To reduce the risk of serious personal injury, remove
PROBLEMS
Loose screws.
Worn or damaged o-rings or seals.
Inadequate air supply.
Inadequate lubrication.
Worn or damaged valve.
Loose screws.
Worn or damaged o-rings or bumper.
Incorrect fasteners.
Fasteners loaded incorrectly
Damaged fasteners. Bent collation wire.
Canister or nose screws loose
Canister is dirty.
Driver tip is worn or damaged.
Worn piston seal.
Worn valve.
15
WALT SERVICE CENTER OR CALL 1-(800)-4-D
e
SOLUTIONS
Tighten screws.
Install overhaul kit.
Verify adequate air supply.
Put 5 or 7 drops of oil into air inlet.
Install valve kit.
Tighten screws.
Install Overhaul Kit.
Verify approved fasteners of correct size and 15°
collation angle.
Verify fasteners are loaded in the correct platform
position.
Replace with undamaged fasteners.
Tighten screws.
Clean magazine.
Install Driver Maintenance Kit.
Install overhaul kit.
Install valve kit.
Contact a D