EP3203-U1
8 CONTROL OF THE AIR-MASSAGE OPERATION
Air massage functions with the operations of the pump unit x 1pc, 3-way electromagnetic valve x 1pc, and 2-way
electromagnetic valve x 2pcs.
1. Air massage is operated by the pump and electromagnetic valves.
2. When not in operation, all the pump and the electromagnetic valves are in Off position.
3. When the Reclining lift motor and the Ottoman lift motor are in operation, the control of air is stopped. (Electromagnetic is
Off. In ventilation.)
4. When you operate the electric reclining lift or the electric Ottoman lift while you operate On/off button or it is in waiting mode,
stop the operation of the pump. (The pressure of electromagnetic valves are maintained.) And after the operation
stop(retracting mode) from the retracting mode and stop mode, or after electric reclining lift or electric Ottoman lift stop in
the waiting mode, air massage stops in 5 seconds.
*After the 3-way electromagnetic valve of Legs big turns Off , turn On the 2-way electromagnetic valve and maintain the
pressure of Legs big.
12