4.2.2 Error codes of panel mechanism
OPEN error
1.Time out error by OPEN position cannot detect.
CLOSE error (ANGLE 1 error)
1.Time out error by ANGLE 1 position cannot detect.
Angle positioning error
Moving to 10 degrees (ANGLE 2 error)
1.Time out error by ANGLE 2 position cannot detect at moving to open position.
2. Missing to ANGLE 1 and detected ANGLE 2 position at moving to open position.
3.Time out error by ANGLE 2 cannot detect at moving to close position.
Moving to 20 degrees (ANGLE 3 error)
1.Time out error by ANGLE 3 position cannot detect at moving to open position.
2. Missing to ANGLE 2 and detected ANGLE 3 position at moving to open position.
3.Time out error by ANGLE 3 cannot detect at moving to close position.
Moving to 30 degrees (ANGLE 4 error)
1.Time out error by ANGLE 4 position cannot detect at moving to open position.
2. Missing to ANGLE 3 and detected ANGLE 4 position at moving to open position.
3.Time out error by ANGLE 4 cannot detect at moving to close position.
Abnormal switch position at moving panel
The panel move to open and close potisiton,detected abnormal switch position.
1-28 (No.MA163)
PANEL ANGLE
1
2
3
4
OPEN
Details
PANEL
CLOSE
10 degrees
20 degrees
30 degrees
OPEN
ERROR CODE
(SERVICE MODE)
MAIN BODY
ERROR CODE
(NORMAL)
ERR
0A01
01
0B06
06
0D21
21
0D22
22
0D23
23
0E31
31
0E32
32
0E33
33
0F41
41
0F42
42
0F43
43
0A00
00