Guide Specifications - Johnson Controls Unitary Products NL024 Technical Manual

R-410a, 13 seer 60 hertz
Table of Contents

Advertisement

546040-BTG-E-0711
amount of field labor. A field supplied and field installed
electrical disconnect switch must be installed.
• Round Duct Flanges - (Factory Supplied - Field
Installed) Equal size, side supply and return duct flanges
allow easy hook-up of ducts.
• Condensate Pan - A non-corrosive, long-lasting, water-
tight pan is positioned below the evaporator coil to collect
and drain all condensate. Less collection of stagnate
condensate will build-up. The condensate pan conforms
to ASHRAE 62-89 standards (Ventilation for Acceptable
Indoor Air Quality).
• Condensate Drain - The 3/4 inch NPTF connection is
rigidly mounted to assure proper fit and leak tight seal.
• Durable Finish - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• Full Perimeter Base Rails - The base rails provide a
solid foundation for the entire unit and protects the unit
during shipment. The rails provide fork lift access from all
sides. On applications where the unit is placed on a pad,
the base will keep the unit off the pad to deter corrosion.
• More Attractive Appearance - A single piece Water
Shed top cover containing a top discharge condenser fan
arrangement requires less square footage on installation
and provides a wider variety of installations. The one
piece design adds greater water integrity.
• Top Discharge - The top discharge condenser fan does
not disrupt neighboring areas or dry-out vegetation
surrounding the unit. The warm air from the top mounted
fan is blown up away from the structure and any
landscaping. This allows compact location on multi-unit
applications.
• Condenser Coil Grille - All models utilize a decorative
"Wire Form" coil guard to provide impact protection
against large objects.
• Low Operating Sound Level - The upward air flow
carries the normal operating noise up and away from the
living area. The rigid top panel effectively isolates any
motor sound. Isolator mounted compressor and the
rippled fins of the condenser coil muffle the normal fan
motor and compressor operating sounds.
• Fan System - 2, 2-1/2 and 3 Ton A/C models operate with
a 3-speed PSC (Permanent Split Capacitor) fan motor. 4
and 5 Ton A/C and all Heat Pump models operate with a
constant torque (X Motor) fan motor with 5 speed taps. All
these units easily match all types of applications and
provide greater on site flexibility to match comfort
requirements.
• Protected Compressor - The compressor is internally
protected against high pressure and temperature. This is
accomplished by the simultaneous operation of high
pressure relief valve and a temperature sensor which protect
the compressor if undesirable operating conditions occur.
• Pressure Switches - High pressure and low pressure/
loss of charge switches standard in all units. On Heat
4
Pump models, when abnormal conditions are sensed
through the pressure switches, the unit will lock-out
preventing further operation until reset or the problem is
corrected.
• Exclusive Coil Design - Grooved copper tubes and
enhanced aluminum fin construction on all indoor coils
and heat pump outdoor coils improve heat transfer for
maximum efficiency and durability or Micro-Channel
aluminum tube, aluminum fin on all cooling outdoor coils
for long lasting durability and efficient operation.
• Low Maintenance - Long life, permanently lubricated
condenser and evaporator fan motor bearings need no
annual maintenance adding greater reliability to the unit.
• Secured Service Access Ports - Protected, externally
mounted, re-usable service access ports are provided on
both the high and low lines for ease of evacuating and
charging the system. No final field mounting required.
• Easy Service Access - A large, single panel covers the
electrical controls makes servicing easy. The blower
compartment has a large panel which when removed will
allow the blower fan assembly to slide-out for ease of
maintenance and trouble shooting.
• Replacement Parts - The installer requires no special
training to replace any of the components of these units
and does not need to maintain an inventory of unique
parts.
Field Installed Accessories
• Wall Thermostat - The units are designed to operate with
24-volt electronic and electro-mechanical thermostats.
• Electric Heat Kit - Available in 4 different kW capacities
(5, 7, 10 and 15 kW). (Single phase only)
• Start Assist Kits - Available for all models.
• Outdoor Thermostat - Available for all heat pump models.

Guide Specifications

GENERAL
Units shall be factory-assembled, single packaged, Electric
Cooling units, designed for outdoor mounted installation. Units
shall have minimum SEER ratings of 13.0. Heat pump 7.7 HSPF.
The units shall be factory wired, piped, charged with R-410A
refrigerant and factory tested prior to shipment. All unit wiring
shall be color coded.
All units shall be manufactured in a facility certified to ISO 9001
standards, and the cooling performance shall be rated in
accordance with DOE and ARI test procedures. Units shall be
certified to UL 1995/CAN/CSA C22.2 No. 236 standards.
UNIT CABINET
1.
1.Unit cabinet shall be constructed of G-90, pre-paint
textured steel, certified at 500 hours salt spray test per
ASTM-B117 standards.
2.
The unit top shall be a single piece "Water Shed" design.
Johnson Controls Unitary Products

Hide quick links:

Advertisement

Table of Contents
loading