  • Page 1 Floating Suction Pressure Control PlantVisorPRO User manual...
  • Page 3: Table Of Contents

    CONTENTS Introduction ........................................3 Installation and registration ..................................3 How to use Floating Suction Pressure Control ............................4 Navigating the pages ....................................4 Opening Floating Suction Pressure Control ............................... 5 Configuring Floating Suction Pressure Control............................5 Starting Floating Suction Pressure Control..............................7 Checking the status of the systems................................
  • Page 5: Introduction

    1. Introduction The PlantVisorPRO Floating Suction Pressure Control plug-in has been designed to reduce the energy consumption of showcases. To do this, it periodically analyses the operation of the showcases associated with the compressor racks that have been enabled, and, based on the duty cycle values calculated for each showcase, automatically modify the set point of the rack.
  • Page 6: How To Use Floating Suction Pressure Control

    Floating Suction Pressure Control 3. How to use Floating Suction Pressure Control The control function must be first configured and then activated. To do this, proceed as follows: Open the plug-in. Choose which systems the control is to act on. Associate these systems with the showcases.
  • Page 7: Opening Floating Suction Pressure Control

    Floating Suction Pressure Control 5. Opening Floating Suction Pressure Control To access the plug-in click and select PLUG-IN: the list of plug-ins installed will be shown: 6. Configuring Floating Suction Pressure Control After having entered the PLUG-IN section, double click Floating Suction Pressure Control: the main page is shown for configuring the control: Code +030220508 - rel.
  • Page 8 Floating Suction Pressure Control Click Configuration: the Systems page is shown, with the list of compressor rack controllers compatible with Floating Suction Pressure Control. On this page, select the systems to be enabled in the plugin. NOTE: any devices not compatible with Floating Suction Pressure Control are not shown in the list. NOTE: a maximum of eight systems can be enabled.
  • Page 9: Starting Floating Suction Pressure Control

    Floating Suction Pressure Control Click Next: the configuration is saved and the main page is shown again, with the graphs already set out for each rack: The plug-in is ready to be started and control the cooling cycle of the showcases based on the default parameters already set. 7.
  • Page 10: Checking The Status Of The Systems

    Floating Suction Pressure Control 8. Checking the status of the systems After having started the control, the trend of the set point on each compressor rack can be checked by reading the graph on the main page. If all the showcases associated with the compressor rack have a duty cycle lower than the maximum set point defined for the showcase, Floating Suction Pressure Control will increase the value of the set point on the compressor rack.
  • Page 11: Customising The Compressor Rack And Showcase Parameters

    Floating Suction Pressure Control 9. Customising the compressor rack and showcase parameters Floating Suction Pressure Control is supplied with standard parameters that manage the operation of the control. Nonetheless, some of the compressor rack parameters or the maximum duty cycle of a showcase can be changed, for example to adjust the algorithm to the specific installation.
  • Page 12: List Of Compressor Rack Parameters

    Floating Suction Pressure Control List of compressor rack parameters Parameter Description Default Current set point Current value of the Set Point variable on the rack Minimum set point Minimum value available for the Set Point variable. Maximum set point Maximum value available for the Set Point variable. Gradient Establishes how much the set point will be increased and decreased by following the calculation of the duty cycle on the showcases...
  • Page 14 Agenzia / Agency: CAREL S.p.A. Via dell’Industria, 11 - 35020 Brugine - Padova (Italy) Tel. (+39) 049.9716611 Fax (+39) 049.9716600 http://www.carel.com - e-mail: carel@carel.com...