6. Timer
7. After completing steps 3 to 6 above, press the Filter
lock in the value.
Note:
Your new settings will be cancelled if you press the Operation mode
before pressing the Filter
8. Press the Operation mode (Back) button
control screen.
9. Press the Timer On/Off button
the timer is running, the timer value is visible on the display. Be sure
that the timer value is visible and appropriate.
<Viewing the Current Simple Timer Settings>
T
M I
E
R
1. Be sure that the simple timer indicator is visible on the screen (at
2. Press the Timer Menu button
screen (at
).
• If the ON or OFF simple timer is running, the current timer value will
appear at
.
• If ON and OFF values have both been set, the 2 values appear al-
ternately.
3. Press the Operation mode (Back) button
play and return to the standard control screen.
<To Turn Off the Simple Timer...>
Press the Timer On/Off button
pears on the screen (at
).
F
<To Turn On the Simple Timer...>
Press the Timer On/Off button
so that the timer setting becomes visible at .
F
Examples
If ON and OFF times have both been set at the simple timer, operation
and display are as indicated below.
Example 1:
Start the timer with ON time set earlier than OFF time
ON Setting :
3 hours
OFF Setting : 7 hours
Hr
ON
AFTER
SIMPLE
Hr
AFTER
OFF
F
F
SIMPLE
SIMPLE
button
button
.
to return to the standard
to start the timer countdown. When
Timer Setting
Hr
O
N
AFTER
OFF
SIMPLE
, so that the "Monitor" appears on the
to close the monitor dis-
so that the timer setting no longer ap-
F
SIMPLE
Hr
ON
AFTER
F
SIMPLE
At Timer Start
Display shows the timer's ON setting (hours
remaining to ON).
At 3 hours after timer start
Display changes to show the timer's OFF set-
ting (hours remaining to OFF).
The time displayed is OFF setting (7 hours) –
ON setting (3 hours) = 4 hours.
At 7 hours after timer start
The air conditioner goes off and will remain off
until it is restarted.
to
Example 2:
Start the timer with OFF time set earlier than ON time
ON Setting : 5 hours
OFF Setting: 2 hours
F
F
F
F
6.1.3. Auto Off Timer
This timer begins countdown when the air conditioner starts and shuts
).
the air conditioner off when the set time has elapsed.
Available settings run from 30 minutes to 4 hours in 30-minute intervals.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at
the same time.
*2. The Auto Off timer will not operate when any of the following condi-
tions is in effect.
The timer is off; the system is in malfunction state; a test run is
in progress; the remote controller is undergoing self-check or
remote controller check; the user is in the process of selecting
a function; the user is in the process of setting the timer; the
MENU
BACK
MONITOR/SET
PAR-21MAA
<How to Set the Auto Off Timer>
1. Be sure that you are at a standard control screen, and that the Auto
Off timer indicator is visible in the display (at
When something other than the Auto Off Timer is displayed, set it to
AUTO OFF TIMER using the function selection of remote controller (see
8.[4]–3 (3)) timer function setting.
2. Hold down the Timer Menu button
Up" appears on the screen (at
(Note that each press of the button toggles the display between "Set
Up" and "Monitor".)
3. Press the appropriate Set Time button
time (at
).
4. Press the Filter
button
Note:
button
before pressing the Filter
5. Press the Operation mode (Back) button
procedure and return to the standard control screen.
6. If the air conditioner is already running, the timer starts countdown
immediately. Be sure to check that the timer setting appears cor-
rectly on the display.
Hr
AFTER
OFF
At Timer Start
Display shows the timer's OFF setting (hours
SIMPLE
remaining to OFF).
At 3 hours after timer start
Hr
ON
AFTER
Display changes to show the timer's ON setting
(hours remaining to ON).
SIMPLE
The time displayed is ON setting (5 hours) – OFF
setting (2 hours) = 3 hours.
At 5 hours after timer start
The air conditioner comes on and will continue to
SIMPLE
run until it is turned off.
AFTER
OFF
AUTO OFF
TEMP.
ON/OFF
ON/OFF
FILTER
DAY
CHECK
TEST
OPERATION
CLOCK
CLEAR
Timer Setting
AFTER
OFF
AUTO OFF
).
for 3 seconds so that the "Set
).
as necessary to set the OFF
to lock in the setting.