SECTION 6
EMERGENCY PROCEDURES
ELECTRICAL
MALFUNCTIONS
VOLTS INDICATION ABOVE GREEN BAND RANGE OR
VOLTS MORE THAN 15
1. MASTER Switch (ALT Only) - OFF
2. Electrical Load - REDUCE as follows:
a. LDG Light Switch - OFF (use as required for landing)
b. NAV Light Switch - OFF
c. STROBE Light Switch - OFF
d. AVN MASTER Switch - OFF
Radio, Transponder, Pitch Trim, and options (MFD,
Autopilot, and PS Intercom), if installed, will be inoperative
with AVN MASTER - OFF.
3. Land as soon as practical.
A fully charged battery in good condition should provide
power under reduced load for 30 minutes.
6-22
POWER
(Continued)
NOTE
NOTE
U.S.
MODEL 162
GARMIN G300
SUPPLY
SYSTEM
162PHUS-00
CESSNA