Hide thumbs Also See for DMD1001:

Advertisement

User Manual
Digital Blood Pressure Monitor
DMD1001
version:1.0
Arm Type
Thank you very much for selecting VIVE™ Digital Blood Pressure Monitor
DMD1001
Please read the user manual carefully and thoroughly to ensure the safe
usage of this product, and retain the manual for reference in case you
have problems.
WWW.VIVEHEALTH.COM
Contact us 24/7 at
www.vivehealth.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DMD1001 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vive DMD1001

  • Page 1 DMD1001 version:1.0 Arm Type Thank you very much for selecting VIVE™ Digital Blood Pressure Monitor DMD1001 Please read the user manual carefully and thoroughly to ensure the safe usage of this product, and retain the manual for reference in case you have problems.
  • Page 2: Table Of Contents

    CATALOG CATALOG Table of Contents INTRODUCTION........................2 General Description Safety Information LCD Display Signal Monitor Components BEFORE YOU START......................6 The Choice of Power Supply Installing and Replacing the Batteries Measurement Principle Setting Date, Time and Measurement Unit MEASUREMENT........................9 Tie the Cuff Select the User Start the Measurement DATA MANAGEMENT......................12...
  • Page 3: Introduction

    Do not begin or end medical treatment. Consult your physician for treatment or advice. If you are taking medication, consult your physician to determine the most appropriate time to measure your blood pressure. Readings taken by the DMD1001 are equivalent to those obtained by Never change a prescribed medication without consulting your physician.
  • Page 4: Lcd Display Signal

    INTRODUCTION INTRODUCTION LCD display signal Monitor Components CUFF AIR HOSE AIR CONNECTOR PLUG MEM BUTTON SET BUTTON START/STOP BUTTON SYMBOL DESCRIPTION EXPLANATION LCD DISPLAY Systolic blood pressure High pressure result Component list of BATTERY COMPARTMENT Diastolic blood pressure Low pressure result pressure measuring system Pulse per minute Beats per minute, BPM...
  • Page 5: Before You Start

    BEFORE YOU START BEFORE YOU START Measurement Principle The Choice of Power Supply This product uses the Oscillometric Measuring method to detect blood pressure. Before every measurement, the unit establishes a “zero pressure” equivalent to the air 1.Battery powered mode: pressure.
  • Page 6: Measurement

    BEFORE YOU START MEASUREMENT Applying the cuff 4.Repeat step 2 and 3 to set 5.Repeat step 2 and 3 to set the [HOUR] the [MONTH] and [DAY]. and [MINUTE]. 1.Apply the cuff on your upper arm. Make sure the position of the tube is off-center;...
  • Page 7: Select The User

    MEASUREMENT MEASUREMENT Select the User Start the Measurement 1.After correctly positioning the cuff and 1.When the monitor is off, press SET button to turn on the monitor. selecting the User ID, press the “START/STOP” Press SET button again to select the User ID between User 1 and User 2. START button to turn on the monitor when the LCD STOP...
  • Page 8: Data Management

    DATA MANAGEMENT DATA MANAGEMENT Recall the Records 3. If you want to check another user’s records, press START/STOP button to turn off the monitor when it is in the memory recall mode. Then press “SET” button to turn on the monitor, press “SET” button again to select the desired 1.
  • Page 9: Delete The Records

    INFORMATION FOR USER DATA MANAGEMENT Tips for Measurement Delete the Records If you did not get the correct measurement, you can delete all It can cause inaccuracy if the measurement is taken in the following circumstances. results by following the steps below. 1.Hold pressing “MEM”...
  • Page 10: About Blood Pressure

    INFORMATION FOR USER ABOUT BLOOD PRESSURE What is systolic pressure and diastolic pressure? Maintenance When ventricles contract and pump blood out of the Systolic Diastolic In order to get the best performance, please follow the instructions heart, the blood pressure reaches its maximum value blood entering blood discharging below.
  • Page 11: Why Does My Blood Pressure Fluctuate Throughout The Day

    ABOUT BLOOD PRESSURE TROUBLESHOOTING This section includes a list of error messages and frequently Why does my blood pressure asked questions for problems you may encounter with your blood fluctuate throughout the pressure monitor. If the product is not operating as you think it should, please check troubleshooting below before arranging for service.
  • Page 12: Specifications

    Relative Humidity 10%-93% For more information about our products, please visit www.vivehealth.com. You can condition Atmospheric Pressure: 50-106 kPa get customer service, usual problems and customer download, VIVE™ will serve you anytime. Measurement perimeter About 8 3/4-16 1/2" (22-42 cm)
  • Page 13: Complied Standards List

    COMPLIED STANDARDS LIST EMC GUIDANCE EMC Guidance Complied Standards List ISO/EN 14971:2012 Medical devices — Application of risk 1. MEDICAL ELECTRICAL EQUIPMENT needs special precautions Risk management management to medical devices regarding EMC and needs to be installed and put into service ISO/EN 15223-1:2012 Medical devices.

Table of Contents