Toshiba rd-xv48dtkb Service Manual page 84

Hdd & dvd / video cassette recorder
Hide thumbs Also See for rd-xv48dtkb:
Table of Contents

Advertisement

BOARD POWER SUPPLY Top View
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
1-14-25
NOTE: BOARD MEANS PRINTED CIRCUIT BOARD.
Because a hot chassis ground is present in the power
supply circut, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly, when troubleshooting this type power supply
circuit, a variable isolation transformer is required.