Lincoln 83668 User Manual

Lincoln 83668 User Manual

Air operated grease pump series "f"

Advertisement

Quick Links

OUTPUT
PER
RESERVOIR
RATIO
STROKE
CAPACITY
(CU. IN.)
4 -1/4 pints
20:1
* .450
(123 cu. in.)
*Based on lubricants that are free from entrapped air. Lubricants that are aerated will reduce output of pump. The
83668 Pump is used as the pumping unit for a Centralized Lubrication System having a single circuit of SL-32 or
SL-33 Injectors. It is an air-operated, single-stroke, spring-return pump that discharges .450 cu. in. into the
circuit for each pump cycle.
MAR – 98
AIR OPERATED GREASE PUMP
AIR
LUBRICANT
INLET
OUTLET
TYPE OF
SYSTEM
1/4" NPT
1/4" NPT
SL-32
Female
Female
SL-33
The total quantity of lubricant needed for the lubrication
cycle of the system must not exceed the lubricant
discharged per pump stroke.
One Lincoln Way
St. Louis, Missouri 63120-1578
(314) 679-4200
Model No. 83668
LUBRICANT OPERATING PRESSURE (PSI)
MINIUM
MAXIMUM
1,200
3,500
with
with
60 PSIG Air
175 PSIG Air

TO FILL RESERVOIR

Use Manual Filler Pump 81834 to fill reservoir
through the filler fitting in the pump body. Attach
coupler on delivery hose to filler fitting. Stroke
filler pump handle until lubricant weepage is noted
at air vent hole in the reservoir (lower portion of
follower must rise beyond air vent hole to expel
entrapped air from lubricant).
the reservoir, caution should be used as extreme
pressure can cause damage to reservoir and
follower assembly.

TO PRIME SYSTEM

SUPPLY LINES: After pump reservoir has been
filled with recommended lubricant, remove all
plugs in dead ends of the injector manifolds
and supply lines. Operate pump until lubricant
flows from any plug opening. Close opening
with plug.
Continue operating pump until
lubricant flows from another plug opening.
Repeat this procedure until all supply lines are
primed.
FEEDER LINES: Fill each feed line with lubricant
before connecting tines to outlet of injectors
and bearings. This will prevent having to cycle
each injector for every inch of feeder line
between injector and bearing.
INJECTORS: Check each individual injector for
proper operation.
Copyright 1998
Printed in U.S.A.
Series "F"
RECOMMENDED
1,500
with
75 PSIG Air
Note: When filling
- C8
Section
- 127I
Page
FORM 402817

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 83668 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lincoln 83668

  • Page 1 *Based on lubricants that are free from entrapped air. Lubricants that are aerated will reduce output of pump. The 83668 Pump is used as the pumping unit for a Centralized Lubrication System having a single circuit of SL-32 or SL-33 Injectors. It is an air-operated, single-stroke, spring-return pump that discharges .450 cu. in. into the circuit for each pump cycle.
  • Page 2 IMPORTANT: Pump must be installed in a vertical position. OPERATION OF THE PUMP Lubricant in the 247210 Translucent Reservoir flows into the cavity in the 247484 Bushing and Plunger Assembly. Compressed air entering the bottom of the 247476 Air Cylinder (1/4" N.P.T. female) moves the 247478 Piston upward.
  • Page 3 NOTE: In reassembling the 84175 Check and Extension Assembly, the vent pressure must be reset. Vent pressure can be varied by the Adjusting Screw, 14288. The recommended pressure setting is 25 P.S.I.G. minimum to 75 P.S.I.G. maximum. An improper setting will affect the pump efficiency. Assemble 14288 with non-hardening Loctite or stake threads after adjusting vent pressure.
  • Page 4 RETAIN THIS INFORMATION FOR FUTURE REFERENCE When ordering replacement parts, list: Part Number, Description, Model Number and Series Letter. LINCOLN provides a Distributor Network that stocks equipment and replacement parts. PAGE 4 FORM 402817...

Table of Contents

Save PDF