Download Print this page

Battery Replacement; Maintenance - IDEAL 61-773 Instruction Manual

1000a trms clamp meters w/tightsight display
Hide thumbs Also See for 61-773:

Advertisement

Measuring Frequency 61-773, 61-775
Press
/ Hz
to toggle
between AC
Current &
Frequency
w/Clamp Head

Battery Replacement:

• Ensure test leads are disconnected from
circuit or components.
• Remove test leads from input jacks
on meter.
• Remove the two screws from the
battery cap.
• Remove the battery cap.
• Replace battery with a new 9V battery.
• Assemble the battery cap to the
meter and re-tighten the screws.

Maintenance:

Clean the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
Service and Replacement Parts:
This unit has no user-serviceable parts.
For replacement parts or to inquire about service information contact IDEAL INDUSTRIES,
INC. at 1-877-201-9005 or visit our website www.testersandmeters.com.
Press
/ Hz
to toggle
between ACV
& Frequency
w/Test Leads
Replacement boot is
available.
9
Specifications:
Displays:
4 digit LCD with 9999 counts for both displays with 41 segment
Backlight:
Green illumination with auto-off after 3 minutes
Polarity:
Automatic, positive implied, negative (-) polarity indication.
Overrange:
"OL" indication is displayed.
Zero:
Automatic
Display (Measure) Rate: Display updates 2 times per second, nominal.
Auto Power Off:
After 30 minutes of non-use.
Battery Life:
100 hours continuous with Alkaline (61-773, 61-775)
Low Battery Indication: The "
" appears in the display with insufficient voltage for about
one hour. Then "bAtt" then displays for 5 seconds and unit powers
down. Indicator duration varies by battery brand.
Power Supply:
(1) 9V battery (NEDA 1604, JIS 006P, IEC 6F22)
With an isolated battery compartment.
Accuracy:
Stated accuracy at 23°C ±5°C, <75% R.H.
Temperature
0.1 x (specified accuracy) per °C,
Coefficient:
(0°C to 18°C, 28°C to 50°C).
Altitude:
6561.7 ft. (2000m)
Operating Environment: 32°F to 122°F (0°C to 50°C) at < 70% R.H.
Display Environment:
-4°F to 158°F (-20°C to +70°C)
Storage Environment:
-4°F to 140°F (-20°C to 60°C) at < 80% R.H. with battery
removed from meter
Jaw Opening:
2.0" (51mm) conductor
Dimensions:
10.6"H x 4.1"W x 1.9"D (270mmH x 103mmW x 48.5mmD)
Weight:
1.1 lbs. (500g) including battery
Accessories included: Carrying Case, Test Leads with alligator clip, (1) 9V
battery, operating instructions.
Safety:
Complies with UL61010-1 (Second Edition), IEC 61010-2-032,
IEC 61010-031, EN61010-1, EN61010-2-032, EN61010-031
specifications, CAN/CSA C22.2 no. 1010.1-92 and CAN/CSA C22.2
No. 1010.2.032-96 Cat IV-600V/Cat III-1000V.
Double Insulation
Instrument has been evaluated and complies with insulation category IV (overvoltage
category IV). Pollution degree 2 in accordance with IEC-644. Indoor use.
N12966
10