Settings

Alarm Settings

Setting
Description
Alarm Buffer,
A pre-determined amount of memory
Overwrite
is used to store images before and
after an alarm event. If the quantity of
images exceeds the allotted amount,
select whether to overwrite previously
stored contents, oldest first. Select
either [ON] (overwrite) or [OFF] (no
overwrite).
Alarm pop-up
Select whether a pop-up window
window
should appear when an alarm event
occurs: either [Enable] (display pop-
up) or [Disable] (no pop-up).
Switch an image
Select whether to switch the display to
when Alarm is ON
the alarm-detecting camera when an
alarm event occurs: either [Enable] or
[Disable] switching.
Relay-OUT at
You can select whether to turn the
Alarm
relay output on or not when an alarm
occurs, by setting to [Enable]
(activates the function) or to [Disable]
(deactivates the function).
The following settings are made through screens that
are displayed for [Input 1] (Alarm Input 1) to [Input 4]
(Alarm Input 4).
Setting
Description
Alarm Enabled
Alarm input is enabled when this box is
checked.
Always
Alarm input is always enabled when
this radio button is selected.
Restricted
Alarm input is enabled for a specific
Between
time of day when this radio button is
selected.
Start
When the [Restricted Between] radio
button is selected, enter the start time
here.
Stop
When the [Restricted Between] radio
button is selected, enter the stop time
here.
Mon to Sun
Check the boxes to specify particular
days on which the alarm input should
be enabled.
Alarm ON at:
Check this box to have a rising alarm
Positive-edge
input signal indicate the occurrence of
an alarm event.
Alarm ON at:
Check this box to have a falling alarm
Negative-edge
input signal indicate the occurrence of
an alarm event.
Image every X
Select the storage interval for images
second(s)
during an alarm event.
Number of PRE
Enter the number of images (0 to 10)
alarm images
to be saved prior to an alarm event.
Number of POST
Enter the number of images (0 to 50)
alarm images
to be saved after an alarm event.
14
Setting
Description
Alarm duration
Enter the time (seconds) from an
alarm occurrence until the alarm mode
is cleared.
No Upload
Select this radio button to disable
transfer of saved images.
Upload Via FTP
Select this radio button to transfer
saved images by FTP.
Host Name
Enter the host name of the transfer
destination.
User Name
Enter the user's name on the host at
the transfer destination.
Password
Enter the password of the above user.
Upload Via e-mail
Select this button to send a saved
(one image only)
image as an e-mail attachment.
To Email
Enter the mail address of the
destination for image files. Multiple
addresses may be entered by
separating with commas. Up to 100
characters may be entered.
Subject
Enter the title text for the e-mail.
Text
Enter the body text for the e-mail.
Camera Link
Check this box to include in the e-mail
a link to the real-time image on the
camera where an alarm event occurs.
Use Passive Mode
To use Passive mode, select this
check box.
FTP Port Number
Enter the port number.
Upload Path: (FTP
Enter the path of the save destination
only)
for image files sent by FTP to a host.
Base File Name
Enter the file name prefix (the fixed
part of the file name) to be assigned to
image files sent.
Date/Time Suffix
Select this radio button to append the
date and time to the base file name.
Sequence
Select this radio button to append a
Number
sequential number to the prefix.
Suffix set to
Maximum
Sequence
When appending a sequential number
Number
to the prefix, select this radio button
Suffix up to:
and enter a value to specify a
maximum for the number.
Note
• When the Alarm function is active, you cannot set the
[Quality] of video images to [Hyper]. For details on
video image settings, see "Video Image Settings"
(page 27).
• Alarm events that occur while writing to alarm
memory are not saved in the memory.
• When an alarm occurs immediately after writing to
alarm memory, the number of images stored may not
match the value set for the number of PRE alarm
images.