Water Connections - Pentair Pool Products MiniMax 200 Operation & Installation Manual

Pool & spa heaters
Table of Contents

Advertisement

Available languages

Available languages

Section III. Installation

WATER CONNECTIONS

Reversing Headers —
Reversible Inlet/Outlet Connection
The MiniMax NT Series heater is factory assembled
with right side inlet/outlet water connections. The
inlet/outlet header can be reversed for left side water
connections without removing the heat exchanger.
Reversing Water Connections
Tools required:
Phillips Screw Driver
9/16 in. Socket and Wrench
1/2 in. & 9/16 in. Open Wrench
1. Remove the right and left large access doors. It is
not necessary to remove the top of the heater to
gain access to the headers.
2. Disconnect all wires from the high-limit
switches except the short jumper wire.
NOT remove
3. Disconnect the water pressure switch wiring.
4. Disconnect the temperature sensor wires from
the circuit board and feed them back to the
header.
5. Remove the 8 bolts holding the main inlet/outlet
head.
8
NOTE

Advertisement

Table of Contents
loading

Table of Contents