Section 1: Intellichlor Control Panel; Salt Level Status Leds; Status Leds - Pentair IntelliChlor IC20 Installation And User Manual

Electronic chlorine generator
Hide thumbs Also See for IntelliChlor IC20:
Table of Contents

Advertisement

This section describes the IntelliChlor control panel status LEDs and the More, Less and Boost/On/Off control
buttons.

Salt Level Status LEDs

The salt level is checked daily and is displayed on this section of the unit.
Green: Good salt. The water salt level is above 2900 ppm, the
cell will produce chlorine. Flash green: Salt is above 4200 ppm.
Chlorine is being produced but the pool water may be corrosive to
other pool equipment. Water needs to be drained and refilled one
foot at a time until the salt level is lowered.
Yellow: Low salt. The water salt level is between 2500 ppm and
2900 ppm, salt should be added to the pool. The cell will continue
to produce chlorine, but will be at a reduced level.
Red: Very low salt. The water salt level has fallen below 2500
parts per million (ppm). The cell will not produce chlorine until
additional salt is added.

Status LEDs

Pwr: Shows the condition of the system:
Red: An error is occurring in the system. Service is needed.
Green: The system is operational and ready.
Cell: This light is on if the cell is producing chlorine.
Red: Water temperature is below 52° F, cell is shut off to extend
warranty.
Green (flashing): Cell is bad, may have calcium buildup, time to
clean, although it is still producing chlorine.
Green: Cell is good and producing chlorine
Blank: Cell is off and not producing chlorine. It may be in an
off-period of the sanitizing cycle and will return on shortly.
Life: The cell is designed to operate for approximately 10,000 hours
before replacement is needed or approximately five years of average use.
Green (flash): The cell is over 10,000 hours of life, replace soon.
Green: The cell is under 10,000 hours of life, good.
Flow: This light indicates water is flowing through the cell to produce
chlorine.
Red: Insufficient water flow through the cell, no chlorine will be
produced.
Green: Sufficient water to produce chlorine.
IntelliChlor Control Panel
3077230
IntelliChlor Installation and User's Guide
Section 1
Conforms to
UL STD 1081
US
5

Hide quick links:

Advertisement

Table of Contents
loading