Operating; 3- Instructions; Introduction; Shipping Information - Fluke 8600A Instruction Manual

Table of Contents

Advertisement

8600A
Section
2
Operating
Instructions
2-1.
INTRODUCTION
2-2.
This
section
of
the
manual
contains information
re-
garding
installation
and
operation
of
the
Model
8600A
DMM.
It
is
recommended
that the
contents of
this
section
be
read
and understood
before
any
attempt
is
made
to
operate the
instrument.
Should any
difficulties arise
during operation,
please
contact
your
nearest
John
Fluke
Sales
Representative
or the
John
Fluke Mfg.
Co., Inc.,P.O.
Box43210,
Mount-
lake Terrace,
WA
98043;
telephone (206) 774-2211.
A
list
of
Sales
Representatives
is
located
in
Section 7
of
this
manual.
2-3.
SHIPPING
INFORMATION
2-4.
The
8600A
is
packaged and
shipped
in
a
foam-
packed
container.
Upon
receipt
of
the instrument,
a
thorough
inspection
should be
made
to reveal
any
possible
shipping
damage.
Special instructions for inspection
and
claims
are
included
in
the shipping carton.
2-5.
If
reshipment of the instrument
is
necessary, the
original
container should
be
used.
If
the
original
container
is
not
available,
a
new
container can be obtained
from
the
John
Fluke Mfg.
Co.,
Inc.
Please reference the
instrument
model
number when
requesting a
new
shipping container.
2-6.
INPUT
POWER
2-7.
The
8600A
can be operated
from
100,
1
15,
or
230V
ac
50
or
60
Hz
power
lines,
as selected
by
line
power
select
switch S14. Before connecting the instrument
to
line
power, check
and,
if
necessary,
set
the instrument
for
operation
at
local
line
voltage
as follows: (the
following
procedure should be
carried
out only
by
qualified per-
sonnel)
CAUTION!
Refer to Section
6 Option
—01
for
requirements
of
line
voltage
change
for
8600A -01
instruments.
a.
Remove
the
phillips
screw
from
the
rear
of
the
instrument.
b.
Remove
the
case; pull
it
straight
back from
the
front panel.
c.
Locate
the
power
selection switch;
near the
rear
or
the
main pcb
assembly.
d.
For 100
or
115V
ac
operation position the
slide
switch
so that
115
appears
in
the
slide
aperture.
For
230V/240V
ac operation
set
the
switch
so
230
appears.
e.
Replace
the case
and
phillips
screw.
2-8.
The
rear
panel
power
input
connector
is
a three-
prong,
U-ground connector which
permits the instrument
to
be connected,
via
the
power
cord, to the appropriate
line
power.
The
offset
prong
on
this
connector
is
connected
to
the
8600A
power
supply,
and
should be connected,
via
the
power
cord,
to a
high quality earth
ground.
2-9.
RACK
INSTALLATION
2-10.
The
8600A
is
designed
for either
bench-top
use or
for installation
in a
standard 19-inch
equipment
rack using
an optional accessory rack
mounting
kit.
Rack mounting
kits are available for
left,
right,
center, or side-by-side
mounting
of the
8600A.
Information
regarding
installation
of
the
rack-mounting
accessories
is
given
in
Section
6 under
Rack
Installation.
2-11.
OPERATING FEATURES
2-12.
The
location
of
all
8600A
controls, indicators
and
connectors
are
shown
in
Figure
2-1,
and
described
in
Table
2
-
1
.
1/77