i3 International SAN iS316 User Manual page 81

Table of Contents

Advertisement

INFO
Volt recovery
WARNING
Therm warn OT
WARNING
Therm warn UT
WARNING
Therm fail OT
WARNING
Therm fail UT
INFO
Therm recovery
INFO
JBOD HDD path NG
INFO
PD RPS started L2F
INFO
PD RPS started F2L
INFO
PD RPS started F2F
INFO
PD RPS finished L2F
INFO
PD RPS finished F2L
INFO
PD RPS finished F2F
ERROR
PD RPS failed L2F
ERROR
PD RPS failed F2L
ERROR
PD RPS failed F2F
ERROR
PD VD read write
fault
ERROR
PD IO retry fault
ERROR
PD substitute L2F
ERROR
PD substitute F2L
ERROR
PD substitute F2F
HAC Events
Level
Type
INFO
RG owner changed
INFO
Force CTR write
through
INFO
Restore CTR cache
mode
INFO
Failover complete
INFO
Failback complete
INFO
CTR inserted
ERROR
CTR removed
ERROR
CTR timeout
ERROR
CTR lockdown
ERROR
CTR memory NG
ERROR
CTR firmware NG
ERROR
CTR lowspeed NG
UNDER
Voltage of <string> in JBOD <string> is NORMAL
Temperature of <string> read as <string> in JBOD <name> is
OT WARNING
Temperature of <string> read as <string> in JBOD <name> is
UT WARNING
Temperature of <string> read as <string> in JBOD <name> is
OT FAILURE
Temperature of <string> read as <string> in JBOD <name> is
UT FAILURE
Temperature of <string> in JBOD <name> is NORMAL
Path redundancy to JBOD <name> PD <number> is lost
Assign JBOD <name> PD <slot> to replace PD <slot>.
Assign PD <slot> to replace JBOD <name> PD <slot>.
Assign JBOD <name> PD <slot> to replace JBOD <name> PD
<slot>.
PD <slot> is replaced by JBOD <name> PD <slot>.
JBOD <name> PD <slot> is replaced by PD <slot>.
JBOD <name> PD <slot> is replaced by JBOD <name> PD
<slot>.
Failed to replace PD <slot> with JBOD %4d PD <slot>.
Failed to replace JBOD <name> PD <slot> with PD <slot>.
Failed to replace JBOD <name> PD <slot> with JBOD <name>
PD <slot>.
Read error at LBA <address>-<address> of JBOD <name> PD
<slot> and rewrite failed at LBA <address>-<address> of VD
<name>.
Over I/O retry limit in last 10 minutes on JBOD <name> PD
<slot>, replacing the disk is highly recommended.
Over I/O retry limit in last 10 minutes on PD <slot>, the disk is
disabled for automatic rebuilding with JBOD <name> PD <slot>.
Over I/O retry limit in last 10 minutes on JBOD <name> PD
<slot>, the disk is disabled for automatic rebuilding with PD
<slot>.
Over I/O retry limit in last 10 minutes on JBOD <name> PD
<slot>, the disk is disabled for automatic rebuilding with JBOD
<name> PD <slot>.
Description
The preferred owner of RG <name> has been changed to
controller <number>.
Controller <number> forced to adopt write-through mode on
failover.
Controller <number> restored to previous caching mode on
failback.
All volumes in controller <number> completed failover process.
All volumes in controller <number> completed failback process.
Controller <number> is inserted into system
Controller <number> is removed from system
Controller <number> gets no response
Controller <number> is locked down
Memory size mismatch
Firmware version mismatch
Low speed inter link is down