i3 International SAN iS316 User Manual page 79

Table of Contents

Advertisement

WARNING
Scrub data
recovered
WARNING
Scrub recovered
data
WARNING
Scrub parity
recovered
INFO
PD freed
INFO
RG imported
INFO
RG restored
INFO
VD restored
INFO
PD scrub started
INFO
Disk scrub finished
INFO
Large RG created
INFO
Weak RG created
INFO
RG size shrunk
INFO
VD erase finished
WARNING
VD erase failed
INFO
VD erase started
WARNING
RG disk missing
ERROR
PD VD read write
fault
ERROR
PD IO retry fault
ERROR
PD substitute L2L
Snapshot Events
Level
Type
WARNING
Snap mem
WARNING
Snap space overflow
WARNING
Snap threshold
INFO
Snap delete
INFO
Snap auto delete
INFO
Snap take
INFO
Snap set space
INFO
Snap rollback started
INFO
Snap rollback
finished
WARNING
Snap quota reached
INFO
Snap clear space
iSCSI Events
Level
Type
INFO
iSCSI login accepted
INFO
iSCSI login rejected
INFO
iSCSI logout recvd
Battery Backup Events
Level
Type
INFO
BBM start syncing
INFO
BBM stop syncing
<address> when checking parity on VD <name>.
The data at LBA <address>-<address> is recovered when
checking parity on VD <name>.
A recoverable read error occurred at LBA <address>-<address>
when checking parity on VD <name>.
The parity at LBA <address>-<address> is regenerated when
checking parity on VD <name>.
PD <slot> has been freed from RG <name>.
Configuration of RG <name> has been imported.
Configuration of RG <name> has been restored.
Configuration of VD <name> has been restored.
PD <slot> starts disk scrubbing process.
PD <slot> completed disk scrubbing process.
A large RG <name> with <number> disks included is created
A RG <name> made up disks across <number> chassis is
created
The total size of RG <name> shrunk
VD <name> finished erasing process.
The erasing process of VD <name> failed.
VD <name> starts erasing process.
RG <name> cannot be activated because of missing disks.
Read error at LBA <address>-<address> of PD <slot> and
rewrite failed at LBA <address>-<address> of VD <name>.
Over I/O retry limit in last 10 minutes on PD <slot>, replacing the
disk is highly recommended.
Over I/O retry limit in last 10 minutes on PD <slot>, the disk is
disabled for automatic rebuilding with PD <slot>.
Description
Failed to allocate snapshot memory for VD <name>.
Failed to allocate snapshot space for VD <name>.
The snapshot space threshold of VD <name> has been reached.
The snapshot VD <name> has been deleted.
The oldest snapshot VD <name> has been deleted to obtain extra
snapshot space.
A snapshot on VD <name> has been taken.
Set the snapshot space of VD <name> to <number> MB.
Snapshot rollback of VD <name> has been started.
Snapshot rollback of VD <name> has been finished.
The quota assigned to snapshot <name> is reached.
The snapshot space of VD <name> is cleared
Description
iSCSI login from <IP> succeeds.
iSCSI login from <IP> was rejected, reason [<string>]
iSCSI logout from <IP> was received, reason [<string>].
Description
Abnormal shutdown detected, start flushing battery-backed data
(<number> KB).
Abnormal shutdown detected, flushing battery-backed data
79

Advertisement

Table of Contents
loading

Table of Contents