Level
Type
INFO
PD inserted
WARNING
PD removed
ERROR
HDD read error
ERROR
HDD write error
ERROR
HDD error
ERROR
HDD IO timeout
INFO
PD upgrade started
INFO
PD upgrade finished
WARNING
PD upgrade failed
INFO
PD RPS started L2L
INFO
PD RPS finished L2L
ERROR
PD RPS failed L2L
Hardware Events
Level
Type
WARNING
ECC single
ERROR
ECC multiple
INFO
ECC dimm
INFO
ECC none
INFO
SCSI bus reset
ERROR
SCSI host error
ERROR
SATA enable device
fail
ERROR
SATA EDMA mem
fail
ERROR
SATA remap mem
fail
ERROR
SATA PRD mem fail
ERROR
SATA revision id fail
ERROR
SATA set reg fail
ERROR
SATA init fail
ERROR
SATA diag fail
ERROR
Mode ID fail
ERROR
SATA chip count
error
INFO
SAS port reply error
INFO
SAS unknown port
reply error
INFO
FC port reply error
INFO
FC unknown port
reply error
INFO
Port linkup
INFO
Port linkdown
EMS Events
Level
Type
INFO
Power install
ERROR
Power absent
INFO
Power restore
ERROR
Power fail
WARNING
Power detect
INFO
Fan restore
ERROR
Fan fail
Description
Disk <slot> is inserted into system
Disk <slot> is removed from system
Disk <slot> read block error
Disk <slot> write block error
Disk <slot> is disabled
Disk <slot> gets no response
PD [<string>] starts upgrading firmware process.
PD [<string>] finished upgrading firmware process.
PD [<string>] upgrade firmware failed.
Assign PD <slot> to replace PD <slot>.
PD <slot> is replaced by PD <slot>.
Failed to replace PD <slot> with PD <slot>.
Description
Single-bit ECC error is detected at <address>
Multi-bit ECC error is detected at <address>
ECC memory is installed
Non-ECC memory is installed
Received SCSI Bus Reset event at the SCSI Bus <number>
SCSI Host allocation failed
Failed to enable the SATA pci device
Failed to allocate memory for SATA EDMA
Failed to remap SATA memory io space
Failed to init SATA PRD memory manager
Failed to get SATA revision id
Failed to set SATA register
Core failed to initialize the SATA adapter
SATA Adapter diagnostics failed
SATA Mode ID failed
SATA Chip count error
SAS HBA port <number> reply terminated abnormally
SAS frontend reply terminated abnormally
FC HBA port <number> reply terminated abnormally
FC frontend reply terminated abnormally
The Port <number> link status is changed to Up.
The Port<number> link status is changed to Down.
Description
Power (<string>) is installed
Power (<string>) is absent
Power (<string>) is restored to work.
Power(<string>) is not functioning
PSU signal detection(<string>)
Fan (<string>) is restored to work.
Fan (<string>) is not functioning