i3 International SAN iS316 User Manual page 80

Table of Contents

Advertisement

INFO
BBM installed
INFO
BBM status good
INFO
BBM status charging
WARNING
BBM status fail
INFO
BBM enabled
INFO
BBM inserted
INFO
BBM removed
JBOD Events
Level
Type
INFO
PD upgrade started
INFO
PD upgrade finished
WARNING
PD upgrade failed
INFO
PD freed
INFO
PD inserted
Warning
PD removed
ERROR
HDD read error
ERROR
HDD write error
ERROR
HDD error
ERROR
HDD IO timeout
INFO
JBOD inserted
WARNING
JBOD removed
WARNING
JBOD SMART T.E.C
WARNING
JBOD SMART fail
INFO
JBOD CTR inserted
WARNING
JBOD CTR removed
WARNING
JBOD degraded
INFO
PD dedicated spare
INFO
PD global spare
ERROR
Config read fail
ERROR
Config write fail
DEBUG
PD read error
WARNING
PD write error
INFO
PD scrub started
INFO
PD scrub completed
WARNING
PS fail
INFO
PS normal
WARNING
FAN fail
INFO
FAN normal
WARNING
Volt warn OV
WARNING
Volt warn UV
WARNING
Volt crit OV
WARNING
Volt crit UV
finished
Battery backup module is detected
Battery backup module is good
Battery backup module is charging
Battery backup module is failed
Battery backup feature is <string>.
Battery backup module is inserted
Battery backup module is removed
Description
JBOD <name> PD [<string>] starts upgrading firmware process.
JBOD <name> PD [<string>] finished upgrading firmware
process.
JBOD <name> PD [<string>] upgrade firmware failed.
JBOD <name> PD <slot> has been freed from RG <name>.
JBOD <name> disk <slot> is inserted into system.
JBOD <name> disk <slot> is removed from system.
JBOD <name> disk <slot> read block error
JBOD <name> disk <slot> write block error
JBOD <name> disk <slot> is disabled.
JBOD <name> disk <slot> gets no response
JBOD <name> is inserted into system
JBOD <name> is removed from system
JBOD <name> disk <slot>: S.M.A.R.T. Threshold Exceed
Condition occurred for attribute <string>
JBOD <name> disk <slot>: Failure to get S.M.A.R.T information
Controller(<number>) of JBOD <name> is inserted into system
Controller(<number>) of JBOD <name> is removed from system
JBOD <name> is in degraded mode.
Assign JBOD <name> PD <slot> to be the dedicated spare disk
of RG <name>.
Assign JBOD <name> PD <slot> to Global Spare Disks.
Config read error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
Config write error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
Read error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
Write error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
JBOD <name> PD <slot> starts disk scrubbing process.
JBOD <name> PD <slot> completed disk scrubbing process.
Power Supply of <string> in JBOD <name> is FAIL
Power Supply of <string> in JBOD <name> is NORMAL
Cooling fan of <string> in JBOD <name> is FAIL
Cooling fan of <string> in JBOD <name> is NORMAL
Voltage of <string> read as <string> in JBOD <name> is WARN
OVER
Voltage of <string> read as <string> in JBOD <name> is WARN
UNDER
Voltage of <string> read as <string> in JBOD <name> is CRIT
OVER
Voltage of <item> read as <string> in JBOD <name> is CRIT
80

Advertisement

Table of Contents
loading

Table of Contents