Continental Girbau CG20 Installation Manual page 24

Table of Contents

Advertisement

2. Technical Gas Data
a. Gas Specifications
Manifold Pressure*
In-Line Pressure
pÜ~ÇÉÇ=~êÉ~ë=~êÉ=ëí~íÉÇ=áå=ãÉíêáÅ=Éèìáî~äÉåíë
* Measured at outlet side of gas valve pressure tap when gas valve is on.
b. Gas Connections
Inlet connection ------------- 3/8" N.P.T.
Inlet supply size ------------- 3/8" N.P.T. (minimum)
Btu/hr input (per dryer) ---- 40,000 (10,080 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.
BTU
MODEL
Per Hour
NUMBER
Rating
CG20
40,000
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas ........................ #31 = 0.1110" (2.8194 mm).
Liquid Propane (L.P.) Gas . #49 = 0.0670" (1.7018 mm).
TYPE OF GAS
NATURAL
3.5 inches W.C.
6.0 - 12.0 inches W.C.
TYPE OF GAS
Natural
kcal/hr
Rating
Qty.
D.M.S.*
10,080
1
#31
LIQUID PROPANE
UKT=ãÄ
10.5 inches W.C.
NQKVO=J=OVKV=ãÄ
11.0 inches W.C.
Liquid Propane
Part
Qty.
D.M.S.*
Number
140868
1
#49
20
OSKN=ãÄ
OTKQ=ãÄ
L.P.
Conversion
Kit
Part
Part Number
Number
140869
883610

Hide quick links: