Download Print this page

U.S. Range 836-1414-1 Installation Instructions Manual page 14

Deep fat fryers

Advertisement

Gas & Electric Equipment Conversion Sheet
DATE:
MARCH 26 1998
MODEL #: 0836-1
SERIAL #: 042584T
TYPE OF GAS BEING USED PRESENTLY: PROPANE
EXISTING MANIFOLD PRESSURE: 10 "WC
ELECTRICAL RATING: N/A
ELEVATION:
UNDER 2000' CONVERSION REQUIRED: PROPANE -- NATURAL
NEW MANIFOLD PRESSURE: 5.0 "WC
COMPANY: ELMER SHULTZ SERVICES
REQUESTED BY: PETE
TELEPHONED
It is recommended that a Garland Authorized Service Centre perform conversions.
Parts and special instructions necessary to complete the conversion are listed below:
Quantity
Part Number
1
228052-9
3
223242-50
Special Instructions:
Please Note: When converting a unit from one type of gas to another, the representative from the authority having jurisdiction
may request the rating plate be changed. If you any questions and/or concerns please call The Garland
Group Service Department at 1-800-427-6668
AMPS
N/A
VOLTS
N/A
PHASE
FAX#:
REGULATOR NAT 1 1/4"
GRIDDLE BURNER ORFICE
609 641 8703
Part Description
List Price ($) ea.

Advertisement

loading

Related Products for U.S. Range 836-1414-1

This manual is also suitable for:

841-1414-1836-1414-2 841-1414-2