Minimum Space Requirements - Tesla Powerwall Owner's Manual

Home battery
Hide thumbs Also See for Powerwall:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
DC disconnect requirements between Powerwall and the inverter are subject to local codes.
Ensure that the installation meets local DC disconnect requirements. Check the inverter
installation manual to understand site connections and overcurrent protection.
All U.S. and Canada electrical installations must be done in accordance with local codes and the
National Electric Code (NEC) ANSI/NFPA 70 or the Canadian Electrical Code CSA C22.1.
All installations must conform to the laws, regulations, codes, and standards applicable in the
jurisdiction of installation.

MINIMUM SPACE REQUIREMENTS

Total ceiling height
Clearance above
Clearance below
Lateral wall space
Clearance from each side
Depth of workspace
3
Depth requirement is typically determined by working clearances required in the local
installation code.
Tesla
3
Site Requirements
2000 mm (6.5 ft )
300 mm (1 ft)
300 mm (1 ft)
1070 mm (42 in)
100 mm (4 in)
762 mm (30 in)