Setting Dynamic Polling Level (Base Station Only) - Wi-LAN AWE120-58 Ultima3 Series User Manual

Advance wireless ethernet bridge
Table of Contents

Advertisement

Configuration

Setting Dynamic Polling Level (Base Station Only)

Dynamic polling improves system performance by reducing overhead due to idle remote units. A base station
automatically learns which remote stations are active and which are idle. The base station waits a brief time
period for a remote to respond to a poll. The remote either does not respond to the poll, or it responds with
a negative acknowledgement. The base then considers the remote to be idle. (This process is called dynamic
time allocation or DTA.) Idle remote units are ignored by the base station for the number of polling rounds
entered in the Dynamic Polling Level field. The higher the dynamic polling level, the more efficient the
throughput and the longer it takes to move a subscriber from an inactive state to an active state. Dynamic
Polling improves system performance whenever there is more than one remote. When there are a large
number of remotes system performance improves significantly.
Note: Polling level is set only at the base station.
To set the dynamic polling level
1. From the Main Menu, select RF Station Configuration and press
Configuration menu is displayed.
H - Help
Station Type
Station Rank (1-1000)
Center Frequency (57410-58338)
Security Password 1
Security Password 2
Security Password 3
Security Password 4
Security Password 5
Scrambling Code
Acquisition Code
Config Test Minutes
Tx Power Level Adjust
Base Station Only Parameters
Repeater Mode
System Symmetry Type
Dynamic Polling Level (1-100)
Remote Station Only Parameters
Remote Unit RF Group (0-63)
Reboot New RF configuration
Save Current Config to Flash
1. Select Dynamic Polling Level and press
2. Type the desired polling level (1-100).
3. Press
. The new setting is displayed in the "New column.
Enter
4. Select Reboot New RF Configuration and press
Login menu is displayed. The unit now runs using the "Current" dynamic polling level for the amount of
time specified by Config Test Minutes.
5. To save the current setting(s) to flash memory, log in, go to the Main Menu, and select Radio Module
Configuration, Save Current Config to Flash. See
Configurations, page
6. Press
to exit to the Main Menu.
Esc
108
Radio Module Configuration
(Hex)
(Hex)
(Hex)
(Hex)
(Hex)
(Hex)
(0-15)
(1-120)
-> 1
112.
New
Current
Remote Unit
Remote Unit
1
1
5.7874 GHz
5.7874 GHz
1
1
10
10
100
100
1000
1000
10000
10000
0
0
0
0
30
30
0 dB
0 dB
off
off
Asymmetric
Asymmetric
1
0
0
Press Enter to Execute
Press Enter to Execute
. The data field highlights.
Enter
. The unit reboots and the AWE 120-58
Enter
. The RF Station
Enter
Flash
Remote Unit
1
5.7874 GHz
1
10
100
1000
10000
0
0
30
0 dB
off
Asymmetric
1
0
Rebooting and Saving RF Module
AWE 120-58 Ultima3 Series User Guide