Richter Optica S6-BL Instructions Manual

Hide thumbs Also See for S6-BL:

Advertisement

Quick Links

Richter Optica
info@richter-optica.com
Instructions for:
S6-BL, S6-TS, S6-SPS, S6-ILST Models

Advertisement

loading

Summary of Contents for Richter Optica S6-BL

  • Page 1 Richter Optica info@richter-optica.com Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models...
  • Page 2 Trinocular port for c-mount adapter Zoom Knob Focusing Holder Clamp Diopter adjustable eyepieces Magni cation locking screw Focusing Knob LED Lights Separate light Built-in Ring intensity control Light Adapter Focusing Knob switches for re ected & transmitted light S6T-BL S6-SPS Zoom Knobs Focus Knobs Trinocular port for...
  • Page 3 Thank you for your purchase of a Richter Optica S6 stereo microscope. The information in this manual is provided to answer most questions that can arise when operating your microscope and to help you avoid unneccesary maintenance expenses in the future. Based on your microscope purchased, the stand may look slightly di erent.
  • Page 4: Operation

    To remove the stage plate on ILST stand: loosen locking set screw on front of base by unscrewing it to the left. For models S6-BL & S6-ILST, there are rocker switches on the base of the microscope. These switches are used to turn the light on/o . The rheostat control knobs will not work if the rocker switch is in the “o ”...
  • Page 5 Focusing Continued: Position focusing knobs in the center of focusing range. Use included allen key to lock and set magni cation if desired. On mounted post models, the height of the viewing head can be adjusted up or down on the post in order to focus on di erent sized objects.
  • Page 6: Maintenance

    MAINTENANCE WARNING: For your own safety, turn switch o and remove plug from power source before maintaining your microscope. If the power cord is worn, cut or damaged in any way, have it replaced immediately to avoid shock or re hazard. Optical Maintenance Do not attempt to disassemble any lens components.
  • Page 7: Optical System

    TROUBLESHOOTING Problem Reason for Problem Solution OPTICAL SYSTEM Too Bright / Dark Brightness degree is not set appropriately Adjust rheostat intensity control Dirt on Specimen Clean the sample Dirt in Field of View Clean the Eyepieces Dirt on Eyepieces Dirt on Objective Lens Clean the Objective Clean the Stage Dirt on Stage...
  • Page 8 EYEPIECE RETICLE INSTALLATION The Richter Optica S6 stereo microscope wide eld high-eyepoint 10x and 15x eyepieces both accept a 25mm diameter reticle. To install the reticle: 1. Remove the eyepiece from the eyetube and turn the eyepiece upside down. 2. Twist out and remove the threaded retaining ring from the bottom of the eyepiece.
  • Page 9 S6 STEREO MICROSCOPE MAGNIFICATION The Richter Optica S6 stereo microscope can acheive di erent magni cations based on the eyepieces and auxiliary lenses used. Refer to the chart below in order to select the proper eyepiece and auxiliary lens accessories to meet your needs.