Atag MadQ/2 User Manual page 33

Q series
Hide thumbs Also See for MadQ/2:
Table of Contents

Advertisement

Parameter 3 - Room sensor display
P P A A R R A A M M E E T T E E R R 0 0 3 3
Setting range: OFF, 1, 2, 3
Factory setting: 1
1 1
H H C C
This parameter activates the room sensor and enables all para-
next parameter
meters which are related with the room temperature.
The following operating modes may be selected:
OFF
1
2
3*
With the room sensor activated the heating circuit is still controlled
depending on weather conditions*, whereby the magnitude of
the influence applied by the room is determined by the following
parameter 04 (ROOM FACTOR).
With the room sensor deactivated the room temperature no lon-
ger appears in the display.
The effect of the room sensor is totally disabled. The
parameters related with the room temperature have no
function. The boilertemperature appears in the stan-
dard display.
The room sensor function is activated, the unit displays
the actual room temperature.
Room
sensor
function
activated,
operation blocked
The effect of the room sensor is completely disabled, the
standard display shows the room temperature.
GB
Note:
The thermostat may not be activated:
– outside the area of unheated rooms, such as cel-
lars etc.
– in apartment blocks with different types of occu-
pation and different room temperatures.
Important: If the actual room temperature drops more than
1 K below the actual room setvalue, an existing
summer shut-down will be disabled.
thermostat
Applications:
All plants requiring monitoring and room temperature control.
* only when the outside sensor is connected
Page GB-33