The following operations must be carried out by qualified personnel only.
ELECTRIC CONNECTIONS AND SETTINGS:
The main heater electricity supply has to be provided with grounding and a magneto-thermal switch
with a differential. The power wire has to be connected to a switch board linked to a disconnecting
switch.
The basic equipment of the heater includes all control and safety devices which can guarantee the correct
functioning of the machine: control board, room thermostat (2), fan and manual safety thermostat are already
connected.
The following operations have now to be carried out:
Plug the power wire in after having read the adhesive label that shows electricity supply characteristics;
After having completed those operations, make carefully sure that all the electric connections match with the
wiring diagram. When the heater gets turned on for the first time, you should make sure that the fan does not
absorb more current than the maximum indicated limit. Eventually, to regulate the burner, follow the instructions
of the burner manual.
HOT AIR DUCTS CONNECTION
The space heater provides heat by releasing and diffusing hot air.
An air head which can be connected to air ducts, if the users chooses this option, is supplied with every machine.
In this case, and in particular if the diameter and length of the ducts get changed, or if the number of bends gets
modified, air output may vary. Consequently, it is very important to check and regulate air output when any
modification is made to air heads or ducts.
In all circumstances, you should make sure that:
The fan engine does not absorb more current than the maximum indicated limit.
The air flow volume matches with its recommended level.
CHIMNEY AND CHIMNEY FLUE CONNECTION
Efficient combustion and trouble-free working of the burner depend on an efficient smoke evacuation:
The pipe which through which smoke passes should as short as possible and ascending.
There should be no sharp bends and the diameter of the pipe should never be reduced.
Every heater should have its own chimney.
The chimney draught should at least enough and adequate for the needs of the equipment.
WASTE PRODUCTS ANALYSIS
The probes to check the combustion waste products composition and smoke temperature have to be positioned as
the picture below indicates.
When those tests have been completed, the hole drilled has to be sealed using a high temperature resistant
material which will ensure that the pipe remains airtight.