Majestic DV360 Homeowner's Installation And Operating Manual page 28

Table of Contents

Advertisement

Vermont Castings Majestic Products DV360/580 Series
Comfort Valve system control sequence of operation with transmitter
f i r e - p a r t s . c o m
Local Path
If manual switch is
set to LOCAL, did
main burner light?
Yes
Transmitter
controls fan
Yes
Turn pilotstat knob
to PILOT to turn
off main burner
Turn pilotstat knob
to OFF to turn
valve completely
off
28
Set manual switch
to local or remote
Light pilot burner
Did the LED stop
blinking?
Release pilotstat
knob
Yes
Turn pilotstat knob
from PILOT to ON
Move switch from
local to remote.
Press any key on
transmitter. Move
switch back to
local
No
Five minute wait
period
Yes
Review LED
failure analysis
Cycle switch once
and leave in
remote. Press any
key on transmitter
for recognition
operation
If the manual switch
is set to REMOTE,
press the mode
button to display
"ON". Does transmit-
ter control the main
burner and fan?
Yes
Does transmitter
change levels of
flame height, fan
speed and set
temperature?
Yes
Set levels of flame
height and fan to
"0" to shut off main
burner and fan
Turn pilotstat knob
to OFF to turn
valve completely
off
Choose Local or
Remote path. Set
switch to manual or
remote
On Path
Move switch from
manual to remote.
Press any key on
transmitter.
No
20002261

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dv580

Table of Contents