Servicing the HE 1 | Calibrating the mechanical components
1
INPUT
OPTICAL
USB
COAXIAL
OFF
UNBALANCED
BALANCED
CROSS FEED
OFF
LOW
HIGH
2
OUTPUT
PHONES
LINE
BOX CONTROL
BOX 1 O/C
BOX 2 O/C
ON
44

Calibrating the mechanical components

If the mechanical components of the HE 1 are decalibrated (e.g. the rotary
switches do not switch correctly, the glass cover does not open or close
correctly or the amplifier tubes do not extend or retract correctly), it might be
necessary to recalibrate them:
1. Set the power switch to
LED goes off (up to 30 seconds).
2. Simultaneously press the
remote control and then set the power switch to
The status LED flashes green. The mechanical components are calibrated
(the rotary switches switch through all the settings one after the other, the
glass cover opens and closes, and the operating elements and the amplifier
tubes extend and retract). Once the calibration process is completed, the
status LED lights up red. The HE 1 is switched off (standby).
When calibrating the mechanical components, make sure to point the
remote control at the remote control sensor located on the front bottom
of the amplifier. Otherwise the amplifier switches on normally.
In order to ensure proper functioning of the HE 1, the mechanical
components are automatically calibrated at predetermined time
intervals. The automatic calibration process starts during switch-off
(standby) of the HE 1.
OFF
to switch the HE 1 off and wait until the status
UNBALANCED
and the
BALANCED
ON
button on the
to switch the HE 1 on.