4

Making a test run

The lift is in mode 0.
1. Sit on the chair base and operate the armrest control.
2. Make a number of trips and check that the chair does not touch the stairs.
a. If this does happen, go to Section 7: 'Extra information'.
b. If this does not happen, go to step 3.
3. Check the entrapment protection mechanism.
a. Make sure there is an obstruction while moving, so that the chair turns around and the lift
comes to a stop.
b. Turn the chair back by removing the obstruction.
c. Operate the lift again.
4. Check the call and park operation when the lift is folded up and driven upwards or downwards.
5. Check whether the lift stops roughly in the centre of the parking place/stop.
6. Check at every parking place/stop that the lift does not start peeping after 15 seconds.
CAUTION
The chair stops automatically at the bottom charging contact. The lift recognises this as
the starting point because the polarity of the lowermost charging contact is the reverse of
the other charging contacts. If this is not the case, drive the lift further as normal. In this
case, check the polarity and the setting of the lowermost charging contact and reverse it
7. Let the user make a test ride, change as necessary
- speed in menu 6
- sound setting in menu 9
- height adjustment of the seat
8. If the test ride is successful, a backup must be made of all the data on the flash card. Go to
mode -9- of the service board, press the [E] button and then go to the 'bu' option with the [D]
or [I] buttons. Then keep the [E] button pressed for 2 seconds. This is confirmed by a 'ping'.
9. Switch the lift back to mode '0' and then switch the lift off/on.
10. Remove the top cover from the drive unit.
11. Remove the flash card from the drive.
12. Secure the flash card in the cap with double-sided tape. Now the settings can no longer be
changed via the service board.
13. Fit the emergency stop frame to the rack with two M6x16 bolts and two nuts.
27