Viking DMOR206SS Service Manual page 29

Over the range microwave oven
Hide thumbs Also See for DMOR206SS:
Table of Contents

Advertisement

PROCEDURE
LETTER
S
RELAY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that these leads remain isolated from other components and oven chassis by using insulation
tape.
6. After that procedure, re-connect the power supply cord.
7. Remove the outer case and check voltage between Pin No. 5 of the 3-pin connector (A) and the
common terminal of the relay RY1 on the control unit with an A.C. voltmeter. The meter should
indicate 120 volts, if not check oven circuit.
Relay Test
These relays are operated by D.C. voltage.
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated............Defective relay.
DC. voltage not indicated.......Check diode which is connected to the relay coil. If diode is good, control
RELAY SYMBOL
RY1
RY2
RY3
RY4
RY5
RY6
RY7
RY8
RY9
RY10
8. Disconnect the power supply cord, and then remove outer case.
9. Open the door and block it open.
10. Discharge high voltage capacitor.
11. Reconnect all leads removed from components during testing.
12. Re-install the outer case (cabinet).
13. Reconnect the power supply cord after the outer case is installed.
14. Run the oven and check all functions.
T
TIMED DEFROST TEST
1. Place one cup of water in the center of the turntable tray in the oven cavity.
2. Close the door, touch the " DEFROST " pad four times.
3. Touch the number 5 pad.
4. Touch " START " pad.
5. The oven will operate as follows.
MENU
CHICKEN
PIECES
6. If improper operation is indicated, the control unit is probably defective and should be checked.
TEST PROCEDURES
unit is defective.
OPERATIONAL VOLTAGE
Approx. 24.0V D.C.
Approx. 24.0V D.C.
Approx. 24.0V D.C.
Approx. 24.0V D.C.
Approx. 24.0V D.C.
Approx. 24.0V D.C.
Approx. 24.0V D.C.
Approx. 24.0V D.C.
Approx. 24.0V D.C.
Approx. 24.0V D.C.
WEIGHT
1ST STAGE
(LBS)
LEVEL
TIME
0.5
70%
28sec.
COMPONENT TEST
CONNECTED COMPONENTS
Oven lamp
Power transformer / Stirrer mootor
Heating element
Turntable motor
Fan motor
Damper motor
Convection motor
Hood lamp
Hood motor
Hood motor (HIGH / LOW selection)
2ND STAGE
LEVEL
TIME
LEVEL
50%
5sec.
30%
29
3RD STAGE
TIME
1min.28sec.