• Scale (2-bits)
The scale fi eld indicates the temperature scale used: 0
indicates Celsius and 1 indicates Fahrenheit.
• Bound Size (3-bits)
The size fi eld indicates the number of bytes used for the
temperature fi lter value. This fi eld must be one (0x01).
• Temperature Filter Lower Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values less than the lower bound. This fi eld must
be between 0F and 124F. By default, this value is 124F (report
all temperature changes).
• Temperature Filter Upper Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values greater than the upper bound. This fi eld
must be between 0F and 124F. By default, this value is 0F
(report all temperature changes).
Thermostat Reporting Filter Report Command Defi nition
7
Command Class = COMMAND_CLASS_CONFIGURATION
Precision (0x00)
• Parameter (8-bit)
The parameter is set to 10 (0x0A) for the temperature
reporting fi lter.
• Temperature Filter Lower Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values less than the lower bound. This fi eld must
be between 0F and 124F. By default, this value is 124F (report
all temperature changes).
54
6
5
Command = CONFIGURATION_SET
Parameter = 0x0A
Temperature Filter Lower Bound
Temperature Filter Upper Bound
4
3
Scale
CT100 Thermostat
Z Wave
2
1
Bound Size (0x01)
®
0