4.3 temperature values modification by pressing the
To modify the room temperature values, proceed as follows:
press the ip button to enable the proGr function;
• press the
button to select the required function as described in the following table:
Function
Display
The set temperature value
coMFr
flashes (factory setting = 20°c)
The set temperature value
econM
flashes (factory setting = 18°c)
The set temperature value
noFrs
flashes (factory setting = 5 °c)
The set temperature value
shoWr
flashes (factory setting = 40°c)
• Press the +/-
button to modify the value of the selected function.
• Press the ip button to ex­it the function.
4.4 programmable sWitching time function (button )
4.4.1 holiDay proGraM function
It is possible to temporary shut off the timing program (section 3.6) for a certain period of time. During this period of time
a minimum room temperature value is guaranteed (default value 5°C). To modify this temperature value see section 4.3
under the entry "noFrs".
To enable the function proceed as follows:
press the
button to set the function to "auto" (symbol
press the
button, the display shows the writing MM 60 and the
Press the +/-
buttons to set the period of the timing program with 10 minutes step. The period of time is settable from
a minimum of 10 minutes to a max­imum of 45 days.
By pressing the +
button after 90 minutes, the display shows "hh 02":.
in this case the period of time is carries out in hours from a minimum of 2 hours to a max­imum of 47 hours, with 1 hour
step.
By pressing the +
button after 47 hours, the display shows "DD 02":
in this case the period of time is carried out in days from a minimum of 2 days to a max­imum of 45 days, with 1 day
step.
instructions pertaininG to the user
Description of function
Boiler operation in heating mode at nominal temperature.
Boiler operation in heating mode at reduced temperature.
Boiler operation in heating mode at room frost protection tem-
perature.
Boiler operation in DHW mode at DHW temperature set.
);
symbols flashing.
In this example the function has a period of 60 minutes.
49
button
925.480.1 - GB