SERVICE PROCEDURES-1
1. Replacing the fuses
This symbol located near the fuse indicates that the
fuse used is show operating type, For continued protection against
fire hazard, replace with same type fuse, For fuse rating, refer to
the marking adjacent to the symbol.
Ce symbole indique que le fusible utilise est e lent.
Pour une protection permanente, n'utiliser que des fusibles de meme
type. Ce demier est indique la qu le present symbol est apposre.
REF NO.
PART NO. DESCRIPTION
F6901,F6902
252099
8A-EAK
F6901,F6902
252198
8A-UL
F6901or,F6902or
252261
8A-T/UL-ST2
F901
252198
8A-UL
F901 or
252261
8A-T/UL-ST2
F902
252076
3.15A-SE-EAK FUSE
F902 or
252242
3.15A-SE-TL250V
F902 or
252276
3.15A-SE-TL250V
F903
252075
2.5A-SE-EAK FUSE
F903 or
252241
2.5A-SE-TL250V
F903 or
252275
2.5A-SE-TL250V
F903
252164
5A-UL/T-237
F903 or
252258
5A-T/UL-ST2
[NOTE]
<DD> : 120V model only
<DC> : 120V model only
<WT> : World wide model only
<GR> : Chinese model only for 220V
<PA> : Australia model only for230V
<PT> : Asian model only for 230V
3. To initialize the unit
This device employs a microprocessor to perform various
functions and operations. If interference generated by an external
power supply, radio wave, or other electrical sauce results in accident
which causes the specified operations and functions to operate
abnormally.
To perform a result, please follow the procedure below.
1. Press and the hold down the VIDEO 1 button , then press the
STANDBY/ON button when the unit is Power ON.
2. After "C le a r" is displayed, the preset memory and each mode
stored in the memory, are initialized and will return to the
factory settings.
4. How to check version of microprocessor?
Main microprocessor Q7008.
1. Press and the hold down the DISPLAY button , then press the
2. Press the STANDBY/ON button to Power Off.
Sub microprocessor Q7502.
NOTES
FUSE
GR,WT,PA,PT
Check is impossible. (Unnecessary)
DC,DD
DC,DD
5. Memory Preservation
DC,WT,DD
DC,WT,DD
This unit does not require memory preservation batteries.
GR,WT,PA,PT
A built-in memory power backup system preserves the contents of
GR,WT,PA,PT
memory during power failures and even when the power cord is unplugged.
GR,WT,PA,PT
The power cord must be plugged in order to charge the backup system.
GR,WT,PA,PT
The memory preservation period after the unit has been turned off varies
GR,WT,PA,PT
depending on climate and placement of the unit. On average, memory
GR,WT,PA,PT
contents are protected over a period of a few weeks after the time the unit
DC,DD
has been turned off.
DC,DD
This period is shorter when the unit is exposed to a very humid climate.

6.Setting the voltage selector

(Worldwide models only)
The Worldwide model has a voltage selector for compatibility with
power systems around the world. Before you plug in this model,
make sure that the voltage selector is set to the correct voltage for
your area. If it isn't, use a small screwdriver to set it as appropriate.
For example, if the voltage in your area is 120 volts (V), set the
selector to "120V. " And if it's between 220 and 230 volts (V), set it
to "220-230V."
STANDBY/ON button when the unit is Power ON.
Version is displayed on FL display only for 3 seconds.
ex.
Version 30212a
TX-SR402/8240/HT-R420
AC OUTLET
SWITCHED
100W MAX.
VOLTAGE
SELECTOR
120 V
220-230 V
VOLTAGE SELECTOR
120V
220-230V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ht-r420Tx-sr8240Rc-518mRc-479s