Rating Plates - Lennox SEREFINA CI1500DVF series Installation Instructions Manual

Direct vent
Table of Contents

Advertisement

MANUFACTURED AT: SANTA TERESA, NM
FOR USE WITH NATURAL GAS.
ALTITUDE
MIN. GAS SUPPLY PRESS ("WC)
PRESS MIN. D'ALIMENTATION ("CE)
MANIFOLD PRESSURE ("WC)
PRESSION CE TUBULURE ("CE)
MANUFACTURER'S RECOMMENDED ORIFICE SIZE
DIMENSION DE L'INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTUH)
ENTRÉE MAX (BTUH)
MIN INPUT (BTUH)
ENTRÉE MIN (BTUH)
ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
OPTIONAL FAN/SOUFFLEUR OPTIONAL
MINIMUM
CLEARANCES TO
COMBUSTIBLE
MATERIAL
DEGAGEMENT
MINIMUM DE
MATERIAUX
COMBUSTIBLES
DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE
VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL.
FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.
N'UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L'APPAREIL.
Do not operate the appliance with glass removed, cracked or broken.
"CAUTION:
Replacement of panel should be done by a licensed or qualified service person."
"This appliance is equipped at the factory for use with natural gas only. Units using
propane must be field converted using the LP conversion kit, P/N LB-102158A"
INAL INSPECTION BY:
FOYER DE CHAUFFAGE AU GAZ A EVACUATION
SERIAL NUMBER/NOMBRE DE SERIE
IIIIIIIIIIIIIIIIIIII
XXXXXXXXXXXXXXXX
18
MODEL NO.
CI1500DVF
SERIES
EQUIPE POUR GAZ NATUREL
0-4500 FT (0-1370 M)
-UNIT/APPAREIL: MILLIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS
SIDEWALLS
FLOOR
CEILING OR ALCOVE HEIGHT
BACK/CORNER 45°
VENT SURFACES: TOP
SIDES
BOTTOM
ALCOVE MAXIMUM DEPTH
MUR ADJACENTS
PLANCHER
PLAFOND OU HAUTEUR D'ALCÔVE
EN ARRIÈRE ET COIN 45 ANGLE
SURFACES D'AERATION: DESSUS
COTES
BAS
PROFONDEUR D'ALCÔVE MAXIMALE
COMBUSTIBLE SOLIDE.
ANSI Z21.88-2002
CSA 2.33-2002
CAN/CGA-2.17-M91
VENTED GAS STOVE HEATERS
XXXXX XXXXX
P/N 9-1452A
MANUFACTURED AT: SANTA TERESA, NM
FOR USE WITH NATURAL GAS.
ALTITUDE
MIN. GAS SUPPLY PRESS ("WC)
4.5"
PRESS MIN. D'ALIMENTATION ("CE)
MANIFOLD PRESSURE ("WC)
3.5"
PRESSION CE TUBULURE ("CE)
MANUFACTURER'S RECOMMENDED ORIFICE SIZE
#37
DIMENSION DE L'INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTUH)
28,000
ENTRÉE MAX (BTUH)
MIN INPUT (BTUH)
17,500
ENTRÉE MIN (BTUH)
ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
OPTIONAL FAN/SOUFFLEUR OPTIONAL
MINIMUM
2"
0"
CLEARANCES TO
62"
4"
COMBUSTIBLE
3"
1"
MATERIAL
1"
48"
DEGAGEMENT
50.8mm
0mm
MINIMUM DE
1574.8mm
101.6mm
MATERIAUX
76.2mm
25.4mm
COMBUSTIBLES
25.4mm
1219.2mm
DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE
VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL.
FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.
N'UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L'APPAREIL.
Do not operate the appliance with glass removed, cracked or broken.
"CAUTION:
Replacement of panel should be done by a licensed or qualified service person." ."
"This appliance is equipped at the factory for use with natural gas only. Units using
propane must be field converted using the LP conversion kit, P/N LB-102158B"
FINAL INSPECTION BY:
P/N 9-1452A
FOYER DE CHAUFFAGE AU GAZ A EVACUATION
SERIAL NUMBER/NOMBRE DE SERIE
MODEL NO.
CI2500DVF
SERIES
EQUIPE POUR GAZ NATUREL
-UNIT/APPAREIL: MILLIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS
SIDEWALLS
FLOOR
CEILING OR ALCOVE HEIGHT
BACK/CORNER 45°
VENT SURFACES: TOP
SIDES
BOTTOM
ALCOVE MAXIMUM DEPTH
MUR ADJACENTS
PLANCHER
PLAFOND OU HAUTEUR D'ALCÔVE
EN ARRIÈRE ET COIN 45 ANGLE
SURFACES D'AERATION: DESSUS
COTES
BAS
PROFONDEUR D'ALCÔVE MAXIMALE
COMBUSTIBLE SOLIDE.
ANSI Z21.88-2002
CSA 2.33-2002
CAN/CGA-2.17-M91
VENTED GAS STOVE HEATERS
XXXXX XXXXX
IIIIIIIIIIIIIIIIIIII
XXXXXXXXXXXXXXXX
0-4500 FT (0-1370 M)
4.5"
3.5"
.121
38,500
25,500
2"
0"
62"
4"
3"
1"
1"
48"
50.8mm
0mm
1574.8mm
101.6mm
76.2mm
25.4mm
25.4mm
1219.2mm
P/N 9-1452F
P/N 9-1452F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Serefina ci2500dvf series

Table of Contents