Time Parameters - Telsyco IPDP – 00 Installation And Operating Instructions Manual

Table of Contents

Advertisement

3.2.3 Time Parameters

After making changes use the save changes button.
1 – max. time, for which the DoorPhone is hanging up, this time can be
extended during call by sign choice from telephone (* or #) – see page 23.
2 – Number of incoming call rings, the DoorPhone pick up after preseted
number of rings. After detection first ring – LED on front panel blinking. The
number can be set from 1 to 9.
3 – max. time [sec] among button presses [range 1-9]
normal buttons
-
switch closing – if time between two next presses is bigger than w
time, the code is not evaluated correctly.
-
dialing – if the button, we are pressing, is the first password number
for switch closing, so the choice is delayed by this w time.
keyboard
-
switch closing – if time between two next presses is bigger than w
time, the code is not evaluated correctly.
dialing the same as of phone, if time after the last pressed button
dialing from memory, if time following the first pressed button is
4 – time [sec] for which the guard will hang up, before repeated dialing (button
pressing during call or dialing, busy tone detection) [range 1-5]
5 – after finishing the dialing it calculates time (ringing tones). If the number
exceeds time in second, it will hang up [range 10-99]. The dialing is
repeated in case, when the dialing mode of 2 groups is set.
6 – In default is status of DoorPhone signalling acoustically. If signalling makes
problem, so this signalling pick up / hang up prohibited.
IPDP - installation and operating instructions
26
is bigger than w time, then the dialing starts. If the number is
incomplete, it is necessary to hang up (X button) and the
dialing will be repeated.
longer than w time, then the entry of memory number has to
be repeated.

Advertisement

Table of Contents
loading

Table of Contents