19. Gas Conversion Procedure
1)
Close the main gas valve.
Turn power OFF (disconnect the power cord).
2)
Remove front cover. (4 screws)
3)
Remove manifold (complete assembly). (7
screws)
4)
Replace the manifold (complete assembly) and
the packing. (7 screws)
Note: Do not lose or damage the O-ring whe
reassembling.
Ensure connections for the solenoid and sparker
lead are made properly.
Infinity REU-3203W
- 41 -
©Rinnai