ELECTRICAL COMPONENTS

3.9 ELECTRICAL COMPONENTS

3.9.1 MOVING THE CONTROLLER BOX OUT OF THE WAY

[B]
[C]
G060R704.WMF
1. Rear cover ( 3.3 EXTERIOR COVERS)
2. Connector cover [A] ( x 1)
3. Four flat cables [B]
4. Connector [C]
5. Swing out the controller box [D] ( x 4).
NOTE: When the controller box is swung out, free-run tests can still be done.
However, because the LD cables are disconnected, no output appears.
3.9.2 MOVING THE HIGH VOLTAGE SUPPLY UNIT - C, B OUT OF
THE WAY
1. Rear cover ( 3.3 EXTERIOR
COVERS)
2. Swing out the high voltage supply unit
[A] ( x 2).
G060
[A]
3-36
[D]
G060R705.WMF
[A]