INSPECTING BURNERS Continued
OPTIONAL HAND-HELD REMOTE CONTROL ACCESSORIES - MRC
NOTICE: Use only alkaline batteries (included with
MRC).
Installing Receiver
1. Disconnect jumper wires from the control valve (see Figure 23).
2. Locate the battery cover on the back of the receiver (see Figure
24).
3. Install 4-AA batteries (included) into receiver before installing into
fireplace.
4. Connect wires from remote receiver to control valve. See instruc-
tions provided with remote control kit for further information.
Figure 23 - Disconnecting Jumper Wires From Control Valve
Requires 4-AA 1.5V
alkaline batteries
Learning
button
Slide
Switch
ON
REMOTE
OFF
Frequency
adjusting
access hole
Remote Receiver
Figure 24 - Attaching Batteries to Receiver
14
WARNING: Turn off the appliance and allow to cool
before cleaning.
CAUTION: You must keep control areas, burners
and circulating air passageways of fireplace clean.
Inspect these areas of fireplace before each use. Have
fireplace inspected yearly by a qualified service person.
Fireplace may need more frequent cleaning due to
excessive lint from carpeting, bedding material, etc.
Only limited cleaning will be required under normal use of this ap-
pliance. Dust the front grate and top of receiver/valve. Do not use
cleaning fluids to clean logs or any other part of the appliance.
If, after a period of use, the flames start to exhibit unusual shapes
and behavior or the burner fails to ignite smoothly, then the burner
holes may require some cleaning. If this happens, we recommend
that you contact your nearest authorized service technician to get
the appliance serviced.
• Keep area around log set clean and clear of debris.
• Periodically inspect the air mixer and burner tube for foreign matter
blocking the air inlet and flame holes.
HIGH ALTITUDE INSTALLATION
When the fireplace is installed at an elevation above 2000 feet, you
may need to decrease the input rating by changing the existing burner
orifice to a smaller size. Reduce input 4% for every 1000 feet above
2000 feet which they are installed. Check with your local gas company
for proper orifice size identification.
High Temperature Limit Switch
The high temperature limit switch is located inside the upper right
hand corner of the firebox. This feature will prevent the fireplace from
operating at abnormally high temperatures. The burner will automati-
cally turn off without interrupting the pilot flame; the limit switch will
lock out and must be reset manually. To reset the limit switch:
1. Turn off the burner by turning the gas control knob clockwise to
the off position.
2. Remove limit switch plate by removing two screws.
3. Carefully pull limit plate out and press the reset button.
4. Mount limit switch plate back using two screws previously re-
moved.
5. Re-light the burner following instructions on page 12.
WARNING: Only a qualified service person should
service the fireplace.