Page 1
Installation, Operation and Maintenance Instructions for Newport Oil Fired Boiler FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician, qualified in boiler installation and maintenance. Improper installation and/or operation could create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death.
ASME codes using heavy CAUTION gauge steel tubes and boiler plate. Newport boilers must not be directly connected The reliable heat exchanger incorporates special to a heating system using oxygen permeable flue baffles to assure quiet and efficient operation and tubing (see warranty).
LAARS Heating Systems Page 4 Fuel Line: A single pipe system of not less 1.8 Jacket (normally fitted) than 3/8" OD copper tubing is recommended when If not fitted, assemble panels in accordance with fuel storage level is not below the fuel unit. A two in struc tions in Figure 4.
Newport Oil-Fired Heater Page 5 It is recommended that a service contract be WARNING ar ranged with a properly equipped serviceman who Flue gases are dangerous - do not operate will be able to do the job efficiently and without mess.
LAARS Heating Systems Page 6 1.20 Maintenance of the Tankless Coil Remove soot and scale deposits from tubes with After several years of use, the water flow through a flexible wire brush, taking care not to damage the coil may become restricted by mineral deposits “ceraform”...
Page 8
LAARS Heating Systems Page 8 Instructions 1. Pre-assemble L/H side (1) and R/H side (2) to front panel (3) with screws. 2. Slide assembled jacket over boiler and secure side panels to base tray. 3. Fix rear panel (4) to sides.
Page 9
Newport Oil-Fired Heater Page 9 Air vent 1¼" min. Fill pipe One-Pipe System Oil tank Valve "P" Burner Boiler Filter "H" Figure 5A Air vent 1¼" min. Two-Pipe Burner System Filter Boiler Fill pipe Valve "H" tank Figure 5B PIPE LENGTHS...
Page 10
LAARS Heating Systems Page 10 Power supply provides disconnect means & overload protection as required. Room Thermostat L1 (Hot) Power Supply 120V Circulator Switch Low Limit Circulator Hi Limit Oil Burner Relay Heating Circulator AQUASTAT RELAY L8124A WIRING ARRANGEMENT FOR “NP” BOILER CONTROLLING OPERATION OF BOILER AND CIRCULATOR Figure 6.
Replacement Parts 2.1 Ordering Information To order or purchase parts for Laars products, contact your nearest Laars dealer of distributor. If they cannot supply you with what you need, contact Laars Customer Service at the address shown on the back cover of this manual.