Changing The Tanning Lamps; Changing The Filters; Notes; General Troubleshooting Guide - PC MARKETING Tropical Series Care, Use And Installation Instructions

Indoor tanning equipment 32 gb, 41 upp
Table of Contents

Advertisement

When re-assembling : Dark glass filter plate - on user's side !!
The face tanner MUST NOT be used without the glass filter plates!!
Extreme care must be taken not to scratch the glass filter plates.
Re-insert the filter plate holder (63) with the cleaned glass filter plates. Screw the filter plate holder in
place again by means of the screw (62).
6.3 Changing the Tanning Lamps (figure 5)
In accordance with previous description, remove the acrylic sheet. Rotate the tanning lamp (71) in either
direction until the contact pins (72) are visible in the groove of the holder (73). Pull the lamp out. Clean the
reflectors by means of a cloth moistened with alcohol. Hold the new tanning lamp horizontally so that the
contact pins are vertically above one another. In this position, press the tanning lamp into the holder.
Rotate or twist the tanning lamp 90 degrees so that the notch (74) in the metal ring at the end of the lamp
is facing upwards and the brighter reflector side of the lamp is facing towards the unit.
• • • • • Changing the short lamps (U-P-P VERSION)
Remove the acrylic sheet as previously described. Rotate the short lamp (75) in either direction so that
one contact pin (76) goes into the grove (77) (which is open at the bottom) of the holder. Pull the short lamp
out downwards. Hold the new short lamp horizontally so that the contact pins (76) are vertically above one
another. In this position, align the lamps into the groove which is open at the bottom. Tilt the lamp so that
one contact pin fits firmly in the wing of the groove. Rotate the lamp so that the second contact pin snaps
into the other wing of the groove.

6.4 Changing the Filters

The air for cooling the unit enters it through micro filter pads. Lint, hair, dust particles etc., are filtered out
there, so that the internal parts of the unit, such as lamps etc., do not have to be cleaned often. After
prolonged use, these filtered-out particles clog the filters and thus impair the cooling of the unit. Therefore,
you must occasionally replace the filter pads to prevent overheating of the unit. The replacement interval is
dependent upon operating times and local environmental conditions.
You must check the filters after every 200 hours of operation; the filters must not be
more then half clogged
Obtain genuine filter pads through PC Marketing or your authorized distributor only.
• • • • • Changing the filter on the lounge (Figure 2)
Pull the front cover (18) off forwards. There is a large filter pad (79) attached to the cover plate (19) with
strips of velcro. Pull off the filter pad and put on the new pad. Press the front cover (18) back into place.
• • • • • Changing the filters on the canopy (Figure 1)
Remove the upper cover (8) by pressing the cover from the rear of the unit in the direction of the middle.
This can then be removed from the large cover (53) using the tabs. The filter pad is now acces-sible. reove
the wire clips (81), change the filter pad and put the wire clips back on. refit the cover (8)

7 NOTES

• Burning in the lamps
Initially, the lamps have slight color differences. This phenomenon disappears after a short time. The lamps
shine less brightly at the ends. This is due to physical reasons and is not a defect in the lamps.
• Replacing the tanning lamps
The output of the lamps gradually decreases over time, and this effect cannot be visually detected. PC
Marketing recommends that fluorescent lamps should be replaced after approximately 800 hours of operation.

8 GENERAL TROUBLESHOOTING GUIDE

Before you begin maintenance and repair work, you must disconnect unit from the
main power supply. Repairs should only be performed by authorized persons. Safety
devices must no be removed or disabled.
• Dark spots at the ends of the lamps
If dark spots are present at the ends of the lamps when they are off, this will not affect the performance of
the unit. However, as a precaution, replace the starter.
Clear glass filter plate - on lamp side !!