Distributed Poller/Reader - Poller/Reader Setup - Paradyne OpenLane SLM 5.5 Administrator's Manual

Paradyne network device administrator's guide
Table of Contents

Advertisement

Distributed Poller/Reader — Poller/Reader Setup
Procedure
Perform the following steps on the prospective Distributed Poller/Reader platform
(172.20.1.20 in the example diagram).
7800-A2-GB32-00
1. Install OpenLane on the Distributed Poller platform. Do not install the
Apache Web server or traps for HP OpenView.
2. Edit /opt/pdn/OpenLane/OLControlConfig to turn off all services
except Management Services, User History Poller, and User History Reader
(1 = on; 0 = off). Change DOMAIN and READER_DOMAIN from default to
the new domain name (poller1 in this example).
Example of the OLControlConfig file:
DOMAIN=default
READER_DOMAIN=default
PARAMS=
RMI=2099
LDAP=3890
DATABASE=1
WEBSERVER=1
MGMTSVCS=1
UHPOLLER=1
UHREADER=1
SNMPPOLLER=0
SCMPOLLER=1
SCHEDRPTS=0
DIRSVCS=1
3. Edit /opt/pdn/OpenLane/database/config/Preferences.dat file
to define the OpenLane Management Server as the Java naming provider.
Change:
java.naming.provider.url=ldap://localhost:3890
to:
java.naming.provider.url=ldap://172.20.1.10:3890
4. Start OpenLane:
cd /opt/pdn/OpenLane
OLControl start
Ignore any Java errors.
January 2002
4. Configuring Distributed Components
Change to poller1
Change to poller1
Change to 0
Change to 0
Change to 0
Change to 0
4-7

Advertisement

Table of Contents
loading

Table of Contents