Function of Display
T he numbers which are displayed on left are the status of indoor unit checking
status through communication with same outdoor unit.
(If it indicates 1, 3 and 7, that means the ADDRESS of indoor unit is set to 1, 3 and 7.)
T he numbers which are displayed on right indicate the ADDRESS of SW01/SW02,
SW03/SW04 and SW05/SW06 in sequential. (If it indicates 0, 1 and 2, that means the
SW01/SW02 is set to 0, the SW03/SW04 is set to 1, and the SW05/SW06 is set to 2.)
I f the communication error occurs in EEV Kit, the Er C0 message will be shown on
the display alternatively.
KEY function
I f you press a KEY on the PCB, the display will show you a step of appropriate
EEV Kit.
KEY No.
K1
K2
K3
K4
Test run
E ach indoor unit runs separately to check pipe connection and address setting.
If all units run at the same time, pipe cross connection and address
mismatching cannot be found.
AVXWN@@_IM_E_31755_5.08.10.indd 11
Meaning
Step of EEV Kit A
Step of EEV Kit B
19 (19 x 10 = 190 STEP)
Step of EEV Kit C
-
Example
-
11
E-