Advertisement

How to use your
Water Heater
Infinity 32
HD 250 E
Your installer is responsible for correct installation.
Installation instructions are located in a pouch attached
to the inside front panel of the water heater.
Temperature
Controlled
Operation
Infinity
26 Internal
Infinity 26
HD 200 E
HD 200 I
24 Hr Hot Water
0800 746624
Infinity 24
In all areas

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the infinity 32 HD 250 E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rinnai infinity 32 HD 250 E

  • Page 1 How to use your Water Heater Infinity Infinity 32 26 Internal Infinity 24 Infinity 26 HD 250 E HD 200 E HD 200 I Your installer is responsible for correct installation. Installation instructions are located in a pouch attached to the inside front panel of the water heater. 24 Hr Hot Water Temperature In all areas...
  • Page 2: Table Of Contents

    CONTENTS FEATURES & BENEFITS ..................2 IMPORTANT INFORMATION ................. 3 OPERATION WITHOUT TEMPERATURE CONTROLLERS ....... 7 TEMPERATURE CONTROLLERS ................8 STANDARD TEMPERATURE CONTROLLERS ........... 9 Using the Infinity with 1 Standard Temperature Controller ....... 10 Using the Infinity with 2 or more Standard Temperature Controller ....11 To Turn Off your hot water system ..............
  • Page 3: Features & Benefits

    Congratulations on purchasing the latest in Technology Advanced Temperature Controlled Rinnai Hot Water System. The Rinnai Infinity NEVER RUNS OUT of hot water. Whilst electricity, water and gas supplies are connected, hot water is available whenever hot water taps are open.
  • Page 4: Important Information

    IMPORTANT INFORMATION Always check water temperature by hand before At low water flows, the hot water unit may go out entering the shower or bath. without warning. If freezing conditions are expected, turn off water Do not touch the unit cover or the flue outlet. and gas, and drain all water from the appliance.
  • Page 5 IMPORTANT INFORMATION Do not clean the Temperature Control with When the hot water tap is open, and hot water is flowing, the water temperature can only be solvents. Use a soft damp cloth. increased to a maximum of 43°C on the Temperature Controller with priority.
  • Page 6 Our Service network personnel are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance needs service, please ring the 0800 Rinnai service contact number on the back of this booklet. Rinnai recommend that this appliance should be serviced every 3 years.
  • Page 7 Do consider setting your Infinity at a This approach can be maximum temp. of 50°C. extremely valuable (Contact Rinnai New Zealand) because it requires a one Do install a child proof tap cover OR, time action for a long- Do install a child resistant tap.
  • Page 8: Operation Without Temperature Controllers

    COLD 55°C The Infinity is factory pre-set to 55°C. If you require greater control over the temperature of your hot water, contact Rinnai about our temperature controllers to allow precise digital temperature control in the range 37°C ~ 55°C. NOTE Controllers can be easily fitted at any time after installation.
  • Page 9: Temperature Controllers

    TEMPERATURE CONTROLLERS The purpose of the Temperature Controllers is to enable the user to have complete control over the hot water unit. Used correctly, the hot water unit will supply hot water at the temperature selected, even when the water flow is varied, or when more than one tap is used. Adjustments to the operation of your hot water unit can be made with any of the Temperature Controllers.
  • Page 10: Standard Temperature Controllers

    STANDARD TEMPERATURE CONTROLLER Standard Kitchen Temperature Controller (MC-91-1A) Temperature Controllers are not required to operate the Infinity unit. They are an optional extra providing control of water temperature. Up to 4 Standard Controllers can be fitted to one Infinity unit. They are normally installed in the areas where the majority of hot water is used, for example, the kitchen, bathroom, ensuite and laundry.
  • Page 11: Using The Infinity With 1 Standard Temperature Controller

    OPERATION WITH STANDARD TEMPERATURE CONTROLLERS Using the Infinity with 1 Standard Temperature Controller Press the ON/OFF button on the Temperature Controller. The yellow ON indicator will glow on the Temperature Controller. This indicates that the hot water unit is ready to supply hot water when a tap is open.
  • Page 12: Using The Infinity With 2 Or More Standard Temperature Controller

    OPERATION WITH STANDARD TEMPERATURE CONTROLLERS Using the Infinity with 2 or more Standard Temperature Controllers Switching the System ‘ON’: The hot water system and all controllers can be switched ON and OFF from any controller by pressing the ‘ON/OFF’ Button as shown. When the system is turned ON the water Temperature display will be lit.
  • Page 13: To Turn Off Your Hot Water System

    OPERATION WITH STANDARD TEMPERATURE CONTROLLERS To TURN OFF your hot water system During normal operation the system is left ‘ON’. Simply press the ON/OFF button on any Temperature Controller (where fitted). This will shut the Infinity down completely including the Temperature Controller digital displays.
  • Page 14: Deluxe Bathfill Temperature Controllers

    DELUXE BATHFILL TEMPERATURE CONTROLLER Deluxe Bathfill Kitchen Temperature Controller Monitor • Each time a button is pressed, a ‘beep’ will sound. • The ‘beep’ sound and the ‘bath fill complete’ buzzer can be muted by pressing the Temperature Controller Up and Down buttons simultaneously for more than 3 seconds. This can be done for each Temperature Controller.
  • Page 15: Deluxe Bathfill Kitchen Temperature Controller (Mc-70-2A)

    DELUXE BATHFILL TEMPERATURE CONTROLLER Deluxe Bathfill Kitchen Temperature Controller (MC-70-2A) This temperature controller is installed in the kitchen. Each button confirms its operation with a beep and / or voice. Be careful not to get water in the speaker as it may cause damage. CAUTION - 14 -...
  • Page 16: Deluxe Bathfill Bathroom Temperature Controller Monitor

    DELUXE BATHFILL TEMPERATURE CONTROLLER Deluxe Bathfill Bathroom Temperature Controller Monitor • Each time a button is pressed, a ‘beep’ will sound. • The ‘beep’ sound and the ‘bath fill complete’ buzzer can be muted by pressing the Temperature Controller Up and Down buttons simultaneously for more than 3 seconds. This can be done for each Temperature Controller.
  • Page 17: Deluxe Bathfill Bathroom Temperature Controller (Bc-70-2A)

    DELUXE BATHFILL TEMPERATURE CONTROLLER Deluxe Bathfill Bathroom Temperature Controller (BC-70-2A) This temperature controller is installed in the bathroom. Each button confirms its operation with a beep and / or voice. Be careful not to get water in the speaker as it may cause damage. CAUTION - 16 -...
  • Page 18: Using The Infinity With 1 Deluxe Bathfill Temperature Controller

    DELUXE BATHFILL TEMPERATURE CONTROLLERS Using the Infinity with 1 Deluxe Bathfill Temperature Controller When one Temperature Controller is required, the kitchen model must be used (MC-70-2A). Transfer Hot water temp. Clock Hour Min. Sound Cooler Hotter ON/OFF Vol. MC -70 -1A Switching the system ON The hot water system and controller can be switched on and off pressing the ‘ON/OFF’...
  • Page 19: Setting The Sound Volume - Kitchen Bathfill Controller

    DELUXE BATHFILL TEMPERATURE CONTROLLERS Setting the Sound Volume The ‘Sound Vol.’ Button located behind the flip panel is not used when one Kitchen Controller is connected. Using Hot Water Transfer The hot water delivery temperature can be controlled from the Kitchen Controller (MC-70-2A). Hot water temp.
  • Page 20: Using The Infinity With 2 Deluxe Bathfill Temperature Controllers

    OPERATION WITH DELUXE BATHFILL TEMPERATURE CONTROLLERS Using the Infinity with 2 Deluxe Bathfill Temperature Controllers Transfer When 2 Temperature Controllers are used, they must be models MC-70-2A (Kitchen) and BC-70-2A (Bathroom). Ho t wa ter tem p. Clock Hour Min. Hotter Sound Cooler...
  • Page 21 OPERATION WITH DELUXE BATHFILL TEMPERATURE CONTROLLERS Setting the Sound Volume The sound volume for all Temperature Controllers can be set individually. Note that this can be done with the Temperature Controllers switched off. Press the ‘Sound Vol.’ Button located behind the flip panel. Transfer Ho t wa ter temp.
  • Page 22: Deluxe Bathfill Bathroom Controller

    OPERATION WITH DELUXE BATHFILL TEMPERATURE CONTROLLERS Deluxe Bathfill Bathroom Controller Ensure the system is switched ON. When the system is ON, the monitors will be lit. Ensure the ‘Transfer’ button is lit. If not, press the ‘Transfer’ button once. Select the desired temperature using the ‘Hot water temp.’ buttons.
  • Page 23 OPERATION WITH DELUXE BATHFILL TEMPERATURE CONTROLLERS (a) Ensure the system is switched ‘ON’. When the system is ON, the monitors will be lit. Ensure the ‘Transfer’ button is lit. If not, press the ‘Transfer’ button once. (b) Select the desired temperature using the ‘Shower / Bath temp.’ buttons located behind the flip panel.
  • Page 24 OPERATION WITH DELUXE BATHFILL TEMPERATURE CONTROLLERS Step 2 – Activate the automatic Shower saver / Bath fill function and follow the voice prompts. (a) Ensure the system is switched on. When the system is ON, the monitors will be lit. Ensure the ‘Transfer’...
  • Page 25 OPERATION WITH DELUXE BATHFILL TEMPERATURE CONTROLLERS Using the Infinity with 3 Deluxe Bathfill Temperature Controllers Not available for use with Infinity 24 models) When 2 or 3 Temperature Controllers are used for the Infinity, there must be one MC-70-2A (Kitchen) and two BC-70-2A (Bathroom). Transfer Ho t wa ter tem p.
  • Page 26: Using The Infinity With 3 Deluxe Bathfill Temperature Controllers And 1 Standard

    OPERATION WITH DELUXE BATHFILL TEMPERATURE CONTROLLERS Using the Infinity with 3 Deluxe Bathfill Temperature Controllers and 1 Standard Temperature Controller (Infinity 26, Heavy Duty 26 & Heavy Duty 26 - Internal only) When 3 to 4 Temperature Controllers are used for the Infinity, there must be one MC-70-2A (Kitchen), one or two BC-70-2A (Bathroom), and one MC-91-1A (Standard).
  • Page 27: Troubleshooting

    * In all cases, you may be able to clear the Error Code simply by turning the hot water tap OFF, then ON again. If this does not clear the Error Code, try pushing the ON/OFF button OFF, then ON again. If the Error Code still remains, contact Rinnai or your nearest service agent for advice.
  • Page 28: Warranty

    Trade Practices Act and similar State or Territory Laws. Given installation is in accordance with the manufacturers specification, this appliance is warranted by Rinnai for the cost of labour and components in the event of defects arising from faulty materials and/or workmanship with the ensuing warranty conditions.

Table of Contents