Possibilities For Insertion - Electrolux EGT6342NOX User Manual

Hide thumbs Also See for EGT6342NOX:
Table of Contents

Advertisement

Available languages

Available languages

• from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn.
WARNING!
Make sure the flame does not
go out when you quickly turn
the knob from the maximum
position to the minimum
position.
8.5 Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a
correct plug which can hold the load
that the rating plate rates. Make sure
that you install the plug in a correct
socket.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to
the mains plug after the installation.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that the
ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on it.
Connect the brown (or black)
phase cable to the terminal
which has a letter "L". Keep
the phase cable connected at
all times.
8.6 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth wire
must be approximately 2 cm longer than
the brown (or black) phase wire.
8.7 Building In
min.
450 mm
min.
55 mm
30 mm
480 mm
A) supplied seal
B) supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.

8.8 Possibilities for insertion

The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.
ENGLISH
min.
650 mm
560 mm
A
B
13

Advertisement

Table of Contents
loading