Sharp XV-ZW99U Service Manual page 19

Table of Contents

Advertisement

xv-zw99u
CONVERGENCE
AND FOCUS ADJUSTMENT
l
Start the convergence
and focus adjustments
with the top cabinet and the signal
shield removed but the power on. Use the remote control to adjust the image. Take the
following procedures.
1. Focusing the projection lens
(A) Replacing
all the 3 LCD panels
1.
Before replacing all the 3 LCD panels, project an image on the screen and bring it into focus.
2.
Replace the panels with new ones. But until the focus has been completely
readjusted, be careful not to
change the distance between the set and the screen, nor to move the projection
lens focus and zoom
rings.
If the focus is readjusted with a different positional relation, the relation between the projection distance
and the screen size is affected. In other words, a short-distance
image (40 WIDE, for example) may
get out of the focus range, or a long-distance
image (300 WIDE, for example) may come out of focus.
(B) Replacing
1 or 2 of the 3 LCD panels
1.
In adjusting the focus after replacement
of one or two LCD panels, project an image on the screen and
turn the projection
lens focus ring to get the non-replaced
LCD panel into focus.
2.
But until the focus has been completely
adjusted for the new LCD panels, be careful not to change the
distance between the set and the screen, nor to move the projection lens focus and zoom rings.
(If the distance has been changed or the projection lens readjusted,
repeat the above steps 1 and 2.)
2. Adjusting the G-LCD panel
(A) Focus adjustment.
(Make this adjustment
on the white-only
screen.)
1.
Right-and-left
focus adjustment
(r3Y direction)
.
Loosen the lock screws "b" and "c" and insert the eccentric screwdriver
into the notch and hole "b" or "c".
Turn the screwdriver
until the right and left halves on the screen get into focus.
First get the right and left halves in balance.
Then improve the accuracy while making the adjustment
2 below.
1
2.
Top-center-bottom
focus adjustment
(OX and Z directions).
Loosen the lock screws "a" and "b" and insert the eccentric screwdriver
into the notch and hole "a". Turn
the screwdriver
until the top, center and bottom on the screen get into focus.
In adjusting this top-to-
bottom focus, temporarily
tighten the lock screw "b" to fix the 8Y direction adjustment.
3.
Repeat the above steps 1 and 2 to finely adjust the focus.
Finally tighten up all the lock screws.
Notes :
@ Carefully
proceed with the focus adjustment
because the adjusting directions are correlated.
@ In adjusting the convergence
and focus, do not move the projection lens zoom and focus rings until the
end of all the adjustments.
(B) Convergence
adjustment
l
The G-LCD panel has no convergence
adjustment mechanism.
Use this panel as convergence
adjustment
reference.
3. B-LCD panel adjustment
(the same for the R-LCD panel)
(A) Focus adjustment
l
Take the same procedure
as for the G-LCD panel focus adjustment.
Note that the adjustment
range is
small in the Z direction.
If the convergence
is quite different
between the B-LCD and G-LCD panels,
roughly adjust the convergence
first and then the focus.
(B) Convergence
adjustment
l
Use a crosshatch
pattern signal for this adjustment.
Make the adjustment
just for the G-color and the relevant color.
(1)
(2)
(3)
Loosen the convergence
lock screw "d".
With the G-LCD panel's screen center as reference, adjust the B-LCD panel in the X, Y and 8Z directions.
Finally tighten up the convergence
lock screw "d".
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents