13. Press "Min Rx Level" soft key. Thereafter, enter "-110dBm" and press "Min
14. Press "Max Tx Level" soft key. Thereafter, enter "30dBm" and press "Max
15. Press "Access Parameter" soft key. Thereafter, enter "-53dBm" and press
16. Press "Test Mode" soft key. Press "Enable" soft key.
17. Press "Base Service" soft key and "Supported" soft key.
Note: You are entering base services setup.
The displayed values are factory defaults and should not be changed.
Power On Registration: required
Power Off Deregistration: required
Priority Cell: yes
Minimum Mode Service: may be used
Migration: supported
System Wide Services: normal mode
18. Press "More" soft key.
TETRA Voice Services: supported
Circuit Mode Data Service: supported
(Reserved): available
SNDCD Service: available
Air Interface Encryption: not available
Advanced Link: not supported
19. Press the "Return" soft key.
20. Press the "Neighbr Cell" soft key.
21. Verify that the following NEIGHBOUR CELL INFO values are displayed:
10
Rx Level" soft key.
Tx Level" soft key.
"Access Parameter" soft key.
TEST SETUP & TESTING: Typical Test Setup