Gree GWH(07)RA-K3DNA1A/I Service Manual page 44

Table of Contents

Advertisement

S
e t
p
s
7. Remove electric box assy
1
Unplug indoor temp sensor.
2
Remove connection screws of electric box
assy and rear case. Release clasps and
remove connection screws of earthing wire
and evaporator assy. Then remove electric
box assy.
8.Remove evaporator
1
Turn over the rear case assy and remove
connecting pipe clamp. Release clasps
between connecting pipe clamp and rear case
assy. Then remove connecting pipe clamp.
2
Remove connection screws of evaporator
assy and motor clamp. Release clasps
connecting evaporator assy to rear case. Then
remove evaporator assy.
42
P
o r
c
e
d
u
e r
Pipe Clamp
Evaporator Assy
Removal Procedure
Indoor Temp Sensor
Electric Box Cover
Electric Box Assy
Auxiliary Piping