Operating Environment; Mechanical Specifications - Siemens RUGGEDCOM RS900 Installation Manual

Hide thumbs Also See for RUGGEDCOM RS900:
Table of Contents

Advertisement

RUGGEDCOM RS900
Installation Guide
Connector
Mode
Type
SM
SC
SM
SC
i
Typical.
Section 4.5

Operating Environment

Parameter
Ambient Operating Temperature
Ambient Relative Humidity
Ambient Storage Temperature
Section 4.6

Mechanical Specifications

Operating Environment
Cable
i
Tx λ (nm)
Type (μm)
1310
9/125
1310
9/125
Range
-40 to 85 °C
(-40 to 185 °F)
5% to 95%
-40 to 85 °C
(-40 to 185 °F)
Parameter
Dimensions
Weight
Ingress Protection
Enclosure
Tx min.
Tx max.
Sensitivity
(dBm)
(dBm)
(dBm)
-5
0
5
0
Comments
Measured from a 30 cm (12 in) radius surrounding the center of the
enclosure.
Non-condensing
Refer to
Technical Specifications
Rx
Rx
Distance
Saturation
(km)
(dBm)
-34
-3
50
-37
0
90
Value
Chapter 5, Dimension Drawings
1.2 kg (2.7 lbs)
IP40 (1 mm or 0.04 in objects)
20 AWG Galvanized Steel
Chapter 4
Power
Budget
i
(dB)
29
42
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents