Items supporting RS-232C
Additional set-up menu items
<INTERFACE>
Item
No.
Superimposed display
204
RS232C SEL
205
BAUD RATE
DATA LENGTH
206
207
STOP BIT
PARITY
208
209
RETURN ACK
The underlining indicates the factory settings.
RS-232C interface
1. Introduction
1) The VTR can be operated by commands when the RS-232C interface is used.
(See command table on pages E-10 E-12.)
2) Conditions for acknowledging commands from RS-232C interface
The front panel REMOTE/LOCAL switch must be at REMOTE.
The set-up menu item No.204 "RS232C SEL" must be ON.
If the above conditions are not met, [ACK] + [STX]ER001[ETX] is returned to the external unit.
Whether the [ACK] code is returned depends on the setting which has been selected for set-up menu
item No.209 "RETURN ACK."
Setting
No.
Superimposed display
0000
OFF
These settings are for selecting whether the RS-232C
connector is to function when the REMOTE/LOCAL
0001
ON
switch is set to REMOTE.
0: Connector does not function.
1: Connector functions.
0000
These settings are for selecting the RS232C
300
0001
communication speed (baud rate).
600
0002
1200
0003
2400
0004
4800
0005
9600
0000
7
These settings are for selecting the RS-232C data
8
0001
length.
(Unit: bit)
1
These settings are for selecting the RS-232C stop bit
0000
2
0001
length.
(Unit: bit)
0000
NON
These settings are for selecting the none, odd or even
0001
ODE
for the RS-232C parity bit.
0002
EVEN
0: Parity bit is not used.
1: An odd number of bits is used for the parity system.
2: An even number of bits is used for the parity system.
0000
OFF
These settings are for selecting whether the ACK code
0001
ON
is to be returned when a command is received from RS-
232C.
0: ACK code is not returned.
1: ACK code is returned.
– E-4 –
Description of setting